Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 183

The DOI matches its Crossref record.

Total variation regulated EM algorithm [SPECT reconstruction]

Panin, V.Y., Zeng, G.L., Gullberg, G.T. · 1999 · IEEE Transactions on Nuclear Science

Abstract

An iterative Bayesian reconstruction algorithm based on the total variation (TV) norm constraint is proposed. The motivation for using TV regularization is that it is extremely effective for recovering edges of images. This paper extends the TV norm minimization constraint to the field of SPECT image reconstruction with a Poisson noise model. The regularization norm is included in the OSL-EM (one step late expectation maximization) algorithm. Unlike many other edge-preserving regularization techniques, the TV based method depends one parameter. Reconstructions of computer simulations and patient data show that the proposed algorithm has the capacity to smooth noise and maintain sharp edges without introducing over/under shoots and ripples around the edges.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/23.819305

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 183

Metadata

Authors
Panin, V. Y., Zeng, G. L., & Gullberg, G. T.
Venue
IEEE Transactions on Nuclear Science
Published
1999-12
Volume
46
Issue
6
Pages
2202-2210
ISSN
  • 0018-9499 (ISSN-L)
  • 1558-1578
OpenAlex
W2040564415
Cited by
183
References
0
FWCI
1.22
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Total variation regulated EM algorithm [SPECT reconstruction]. https://app.cochat.ai/papers/10.1109/23.819305
The paper
Panin, V. Y., Zeng, G. L., & Gullberg, G. T. (1999). Total variation regulated EM algorithm [SPECT reconstruction]. IEEE Transactions on Nuclear Science. https://doi.org/10.1109/23.819305

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.