Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 937

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

A three‐dimensional statistical approach to improved image quality for multislice helical CT

Thibault, Jean‐Baptiste, Sauer, Ken D., Bouman, Charles A., Hsieh, Jiang·2007·Medical Physics

Abstract

Multislice helical computed tomography scanning offers the advantages of faster acquisition and wide organ coverage for routine clinical diagnostic purposes. However, image reconstruction is faced with the challenges of three‐dimensional cone‐beam geometry, data completeness issues, and low dosage. Of all available reconstruction methods, statistical iterative reconstruction (IR) techniques appear particularly promising since they provide the flexibility of accurate physical noise modeling and geometric system description. In this paper, we present the application of Bayesian iterative algorithms to real 3D multislice helical data to demonstrate significant image quality improvement over conventional techniques. We also introduce a novel prior distribution designed to provide flexibility in its parameters to fine‐tune image quality. Specifically, enhanced image resolution and lower noise have been achieved, concurrently with the reduction of helical cone‐beam artifacts, as demonstrated by phantom studies. Clinical results also illustrate the capabilities of the algorithm on real patient data. Although computational load remains a significant challenge for practical development, superior image quality combined with advancements in computing technology make IR techniques a legitimate candidate for future clinical applications.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1118/1.2789499

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 937

Metadata

Authors
Thibault, J., Sauer, K. D., Bouman, C. A., & Hsieh, J.
Venue
Medical Physics
Publisher
Wiley
Published
2007-10-29
Volume
34
Issue
11
Pages
4526-4544
ISSN
  • 0094-2405 (ISSN-L)
  • 2473-4209
OpenAlex
W2003624223
Cited by
937
References
1
FWCI
16.64
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A three‐dimensional statistical approach to improved image quality for multislice helical CT. https://app.cochat.ai/papers/10.1118/1.2789499
The paper
Thibault, J., Sauer, K. D., Bouman, C. A., & Hsieh, J. (2007). A three‐dimensional statistical approach to improved image quality for multislice helical CT. Medical Physics. https://doi.org/10.1118/1.2789499

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.