Cited by 226Power Quality and HarmonicsElectromagnetic Compatibility and Noise SuppressionAdvanced Electrical Measurement Techniques

A survey of neutral currents in three-phase computer power systems

Gruzs, T.M.·1990·IEEE Transactions on Industry Applications

Abstract

It is shown that the magnitude of the neutral current in three-phase computer power systems depends on the harmonic content and phase balance of the load currents. While very high neutral currents are possible due to the additive nature of triplen harmonic currents, a low percentage of data processing sites in the United States are actually experiencing neutral currents in excess of the rated phase current. However, trends in computer systems make high harmonic neutral currents more likely. Power system problems associated with high harmonic neutral currents include overloaded transformers, voltage distortion, and common mode noise. Whenever three-phase, four-wire power systems are used to supply power to computer systems or other similar electronic loads, the power system design should allow for the possibility of high harmonic neutral current to avoid potential problems.>

Integrity signals

Registry

Crossref · 10.1109/28.55999

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The study in [31] considered grounding resistances of approximately 5 Ω and used a 0.5 V N-G voltage limit as the common-mode threshold for sensitive equipment [32], showing that unbalanced PV connection patterns can drive N-G voltages above this level.

    “The study considered grounding resistances of approximately 5 Ω and used a 0.5 V N-G voltage limit as the common-mode threshold for sensitive equipment [32], showing that unbalanced PV connection patterns can drive N-G voltages above this level.”
  • Other work has investigated integrated three-wire/four-wire approaches for multi-grounded LV networks and highlighted how neutral grounding resistance and unbalanced loading can drive N-G voltages above common mode limits for sensitive equipment.

    “Other work has investigated integrated three-wire/four-wire approaches for multi-grounded LV networks and highlighted how neutral grounding resistance and unbalanced loading can drive N-G voltages above common mode limits for sensitive equipment [31,32].”

Cited by

Sorted by citations

Authors
Gruzs, T. M.
Corresponding author
Gruzs, T.M.
Venue
IEEE Transactions on Industry Applications
Published
1990
Volume
26
Issue
4
Pages
719-725
ISSN
0093-9994 (ISSN-L)
OpenAlex
W2162714477
Cited by
226
References
0
Citations by year
2026: 2 · 2025: 3 · 2024: 2 · 2023: 4 · 2022: 6 · 2021: 4 · 2020: 9 · 2019: 6 · 2018: 11 · 2017: 10 · 2016: 6 · 2015: 17 · 2014: 16 · 2013: 13 · 2012: 9
FWCI
1.44
Type
journal article
Language
en
Open access
closed
Locations
IEEE Transactions on Industry Applications (publishedVersion)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Power Quality and Harmonics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electromagnetic Compatibility and Noise Suppression
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced Electrical Measurement Techniques
Keywords
neutral current, three-phase systems, current harmonics, triplen harmonics, phase balancing, transformer overload, voltage distortion, common-mode noise, power system design

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review