Phase frame analysis of the effects of voltage unbalance on induction machines
Abstract
Operating a three-phase induction motor with unbalanced voltages can lead to excessive heating. The traditional method of analyzing the operating conditions of the motor when unbalanced voltages have been applied has been to use the theory of symmetrical components. The purpose of this paper is to develop a method of analyzing the motor in the "phase frame". The method is then applied to a typical motor to demonstrate the results of operating a motor with unbalanced voltages and the reason why a motor must be derated under these conditions.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Unbalanced voltages cause heat, vibration, and inefficiency by shortening the lifespan of three-phase transformers and power-electronics-based equipment.
“Unbalanced voltages cause heat, vibration, and inefficiency by shortening the lifespan of three-phase transformers and power-electronics-based equipment [3,4].”
From Adaptive Volt–Var Control in Smart PV Inverter for Mitigating Voltage Unbalance at PCC Using Multiagent Deep Reinforcement Learning (2021) · cites this paper as [3]
Cites
Heating of Induction Motors on Unbalanced Voltages
Gafford, B. N., Duesterhoeft, W. C., & Mosher, C. C. (1959) · Transactions of the American Institute of Electrical Engineers Part III Power Apparatus and Systems · doi:10.1109/aieepas.1959.4500314 · Cited by 104 · see citing works
Operation of 3-Phase Induction Motors on Unbalanced Voltages [includes discussion]
Williams, J. E. (1954) · Transactions of the American Institute of Electrical Engineers Part III Power Apparatus and Systems · doi:10.1109/aieepas.1954.4498802 · Cited by 96 · see citing works
Derating of polyphase induction motors operated with unbalanced line voltages
Berndt, M. M., & Schmitz, N. L. (1962) · Transactions of the American Institute of Electrical Engineers Part III Power Apparatus and Systems · doi:10.1109/aieepas.1962.4501391 · Cited by 67 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Assessment of voltage unbalance
von Jouanne, A., & Banerjee, B. (2001) · IEEE Transactions on Power Delivery · doi:10.1109/61.956770 · Cited by 601 · see citing works
Self-excited induction generator research—a survey
Singh, G. K. (2003) · Electric Power Systems Research · doi:10.1016/j.epsr.2003.08.004 · Cited by 237 · see citing works
Santos-Martín, D., Rodríguez-Amenedo, J. L., & Arnalte, S. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.2001907 · Cited by 190 · see citing works
Faiz, J., Ebrahimpour, H., & Pillay, P. (2004) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2004.837283 · Cited by 153 · see citing works
Pillay, P., Hofmann, P., & Manyage, M. J. (2002) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2002.805228 · Cited by 152 · see citing works
Wang, Y. (2001) · IEEE Transactions on Energy Conversion · doi:10.1109/60.937207 · Cited by 148 · see citing works
Gnaciński, P. (2008) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2008.918596 · Cited by 118 · see citing works
Loss of Life in Induction Machines Operating With Unbalanced Supplies
Pillay, P., & Manyage, M. J. (2006) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2005.853724 · Cited by 103 · see citing works
Providing Ride-Through Capability to a Doubly Fed Induction Generator Under Unbalanced Voltage Dips
Santos-Martín, D., Rodríguez-Amenedo, J. L., & Arnaltes, S. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2016965 · Cited by 95 · see citing works
Anwari, M., & Hiendro, A. (2010) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2010.2051548 · Cited by 91 · see citing works
Effects of voltage unbalance on induction motors
Siddique, A., Yadava, G. S., & Singh, B. (2005) · IEEE International Symposium on Electrical Insulation · doi:10.1109/elinsl.2004.1380430 · Cited by 89 · see citing works
Probabilistic three-phase load flow for unbalanced electrical distribution systems with wind farms
Pierluigi Caramia, M. S., Guido Carpinelli, M. S., Pagano, M., & Varilone, P. (2007) · IET Renewable Power Generation · doi:10.1049/iet-rpg:20060013 · Cited by 71 · see citing works
Three-phase inverter-connected DG-units and voltage unbalance
Meersman, B., Renders, B., Degroote, L., Vandoorn, T. L., & Vandevelde, L. (2010) · Electric Power Systems Research · doi:10.1016/j.epsr.2010.11.024 · Cited by 61 · see citing works
Faiz, J., Ebrahimpour, H., & Pillay, P. (2005) · Energy Conversion and Management · doi:10.1016/j.enconman.2005.04.009 · Cited by 59 · see citing works
Mitigating Voltage Unbalance Using Distributed Solar Photovoltaic Inverters
Yao, M., Hiskens, I. A., & Mathieu, J. L. (2020) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2020.3039405 · Cited by 59 · see citing works
A Novel Approach Toward Interpretation and Application of Voltage Unbalance Factor
Kini, P. G., Bansal, R. C., & Aithal, R. S. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.899935 · Cited by 55 · see citing works
Al-Badri, M., Pillay, P., & Angers, P. (2017) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2017.2728786 · Cited by 54 · see citing works
Causes and effects of unbalanced voltages serving an induction motor
Kersting, W. H. (2001) · IEEE Transactions on Industry Applications · doi:10.1109/28.903142 · Cited by 51 · see citing works
Self-citationEnergy conservation potential of an energy audit within the pulp and paper industry in Morocco
Boharb, A., Allouhi, A., Saidur, R., Kousksou, T., & Jamil, A. (2017) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2017.02.090 · Cited by 48 · see citing works
Causes and Effects of Single-Phasing Induction Motors
Kersting, W. H. (2005) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2005.857467 · Cited by 47 · see citing works
Self-citationUnbalance and harmonics detection in induction motors using an optical fiber sensor
Corres, J. M., Bravo, J. A., Arregui, F. J., & Matias, I. R. (2006) · IEEE Sensors Journal · doi:10.1109/jsen.2006.874441 · Cited by 46 · see citing works
Eliminating output distortion in four-switchinverterswith three-phase loads
Peters, G. L., Covic, G. A., & Boys, J. T. (1998) · IEE Proceedings - Electric Power Applications · doi:10.1049/ip-epa:19982022 · Cited by 46 · see citing works
Gnaciński, P. (2007) · Energy Conversion and Management · doi:10.1016/j.enconman.2007.07.033 · Cited by 45 · see citing works
Modeling of doubly fed induction generators for distribution system power flow analysis
Dadhania, A., Venkatesh, B., Nassif, A. B., & Sood, V. K. (2013) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2013.05.025 · Cited by 40 · see citing works
Precise derating of three-phase induction motors with unbalanced voltages
Faiz, J., & Ebrahimpour, H. (2005) · IEEE Industry Applications Society Annual Meeting (IAS) · doi:10.1109/ias.2005.1518352 · Cited by 39 · see citing works
Analysis of voltage unbalance effects on induction motors with open and closed slots
Donolo, P. D., Bossio, G. R., & Angelo, C. H. D. (2011) · Energy Conversion and Management · doi:10.1016/j.enconman.2010.10.045 · Cited by 37 · see citing works
Performance Analysis of Centrifugal Pumps Subjected to Voltage Variation and Unbalance
Kini, P. G., Bansal, R. C., & Aithal, R. S. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.911947 · Cited by 37 · see citing works
Precise derating of three phase induction motors with unbalanced voltages
Faiz, J., & Ebrahimpour, H. (2007) · Energy Conversion and Management · doi:10.1016/j.enconman.2007.03.023 · Cited by 36 · see citing works
Effect of Voltage and Load Variations on Efficiencies of a Motor-Pump System
Kini, P. G., & Bansal, R. C. (2009) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2009.2032628 · Cited by 33 · see citing works
Wang, Y. (2002) · IEEE Power Engineering Society Winter Meeting · doi:10.1109/pesw.2000.849947 · Cited by 33 · see citing works
Jalilian, A., & Roshanfekr, R. (2009) · Electric Power Components and Systems · doi:10.1080/15325000802454476 · Cited by 32 · see citing works
Al-Badri, M., Pillay, P., & Angers, P. (2016) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2016.2533599 · Cited by 30 · see citing works
Quantitative assessment of three phase supply voltage unbalance effects on induction motors
Dekhandji, F. Z., Refoufi, L., & Bentarzi, H. (2015) · International Journal of Systems Assurance Engineering and Management · doi:10.1007/s13198-015-0401-3 · Cited by 29 · see citing works
Derating of an induction machine under voltage unbalance combined with over or undervoltages
Gnaciński, P. (2009) · Energy Conversion and Management · doi:10.1016/j.enconman.2008.12.006 · Cited by 26 · see citing works
Unbalanced distribution power-flow model and analysis of wind turbine generating systems
Abdel‐Akher, M., & Mahmoud, K. (2012) · International Transactions on Electrical Energy Systems · doi:10.1002/etep.1634 · Cited by 26 · see citing works
Experimental Study of Induction Motor Performance with Unbalanced Supply
Reineri, C., Gómez, J. C., Balaguer, E. B., & Morcos, M. M. (2006) · Electric Power Components and Systems · doi:10.1080/15325000500488636 · Cited by 25 · see citing works
Impact of voltage unbalance on the performance of three-phase induction motor
Kini, P. G., Bansal, R. C., & Aithal, R. S. (2006) · South Pacific journal of natural and applied sciences · doi:10.1071/sp06007 · Cited by 24 · see citing works
The performance of a 3-Phase Induction Machine under Unbalance Voltage Regime
Adekitan, A. I., Ogunjuyigbe, A. S. O., Ayodele, T. R., & Samuel, I. A. (2017) · Journal of Engineering Science and Technology Review · doi:10.25103/jestr.105.17 · Cited by 24 · see citing works
Effects of voltage unbalance on IM power, torque and vibrations
Bossio, G. R., Angelo, C. H. D., Donolo, P. D., Castellino, A., & García, G. O. (2009) · IEEE International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED) · doi:10.1109/demped.2009.5292784 · Cited by 23 · see citing works
Influence of the positive sequence voltage on the temperature of three-phase induction motors
Mendes, A. M. S., Quispe, E. C., Fernández, X. M. L., & Cardoso, A. J. M. (2010) · International Conference on Electrical Machines (ICEM) · doi:10.1109/icelmach.2010.5608011 · Cited by 23 · see citing works
Assessment of induction motor performance under voltage unbalance condition
Singh, S. B., Singh, A. K., & Thakur, P. (2012) · International Conference on Harmonics and Quality of Power · doi:10.1109/ichqp.2012.6381280 · Cited by 22 · see citing works
Pillay, P., & Hofmann, P. (2002) · IEEE Power Engineering Society Winter Meeting · doi:10.1109/pesw.2001.917287 · Cited by 22 · see citing works
Data mining approach for supply unbalance detection in induction motor
Çakır, A., Çalış, H., & Küçüksille, E. U. (2009) · Expert Systems with Applications · doi:10.1016/j.eswa.2009.04.006 · Cited by 20 · see citing works
Sudha, M., & Anbalagan, P. (2007) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2007.4460176 · Cited by 19 · see citing works
The influence of grid-connected three-phase inverters on voltage unbalance
Meersman, B., Renders, B., Degroote, L., Vandoorn, T. L., & Vandevelde, L. (2010) · IEEE Power Engineering Society General Meeting · doi:10.1109/pes.2010.5589331 · Cited by 18 · see citing works
Static motor circuit analysis: an introduction to theory and application
Penrose, H. W., & Jette, J. (2000) · IEEE Electrical Insulation Magazine · doi:10.1109/57.855614 · Cited by 18 · see citing works
Adekitan, A. I., Adewale, A. A., & Alashiri, O. (2019) · International Journal of Power Electronics and Drive Systems (IJPEDS) · doi:10.11591/ijpeds.v10.i1.pp93-103 · Cited by 17 · see citing works
Jung, Y., Han, C., Lee, D., Song, S., & Jang, G. (2021) · Applied Sciences · doi:10.3390/app11198979 · Cited by 15 · see citing works
Accurate performance assessment of IM with approximate current unbalance factor for NEMA definition
Singh, S. B., Singh, A. K., & Thakur, P. (2014) · International Conference on Harmonics and Quality of Power · doi:10.1109/ichqp.2014.6842805 · Cited by 15 · see citing works
Capability of synchronous and asynchronous hydropower generating systems: A comprehensive study
Subramanya, K., & Chelliah, T. R. (2023) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2023.113863 · Cited by 14 · see citing works
Fault diagnosis in yaw drive induction motor for wind turbine
Ouanas, A., Medoued, A., Mordjaoui, M., Lebaroud, A., & Sayad, D. (2018) · Wind Engineering · doi:10.1177/0309524x18780379 · Cited by 14 · see citing works
Wide Range Reactive Power Compensation for Voltage Unbalance Mitigation in Electrical Power Systems
Ghaeb, J. A., Alkayyali, M., & Tutunji, T. A. (2021) · Electric Power Components and Systems · doi:10.1080/15325008.2021.2002474 · Cited by 14 · see citing works
Contribution of MV static distributed generation to voltage unbalance mitigation
Savio, A., Bignucolo, F., & Caldon, R. (2016) · AEIT International Annual Conference · doi:10.23919/aeit.2016.7892739 · Cited by 13 · see citing works
Saleh, S. V., & Latify, M. A. (2024) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2024.3370861 · Cited by 13 · see citing works
Causes and effects of unbalanced voltages serving an induction motor
Kersting, W. H. (2002) · IEEE Rural Electric Power Conference (REPC) · doi:10.1109/repcon.2000.848042 · Cited by 12 · see citing works
Self-citationA simple torque estimator for in-service efficiency determination of induction motors
Stopa, M. M., Saldanha, M. A., Luiz, A.-S. A., Baccarini, L. M. R., & Lacerda, G. A. M. (2017) · IEEE Industry Applications Society Annual Meeting (IAS) · doi:10.1109/ias.2017.8101832 · Cited by 11 · see citing works
Coppo, M., Raciti, A., Caldon, R., & Turri, R. (2015) · IEEE International Forum on Research and Technology for Society and Industry (RTSI) · doi:10.1109/rtsi.2015.7325126 · Cited by 11 · see citing works
Masoud, M. I., Abdel-Khalik, A. S., Abri, R. S. A., & Williams, B. W. (2014) · International Conference on Electrical Machines (ICEM) · doi:10.1109/icelmach.2014.6960393 · Cited by 10 · see citing works
Steady-state Performance Assessment of Induction Motor under Unbalanced Voltage Condition
Singh, S. B., & Singh, A. K. (2013) · Electric Power Components and Systems · doi:10.1080/15325008.2013.817492 · Cited by 10 · see citing works
Unsupervised on-line method to diagnose unbalanced voltage in three-phase induction motor
Sheikh, M. A., Nor, N. M., Ibrahim, T., & Irfan, M. (2017) · Neural Computing and Applications · doi:10.1007/s00521-017-2973-0 · Cited by 10 · see citing works
Kersting, W. H., & Rathbun, J. S. (2000) · IEEE Transactions on Industry Applications · doi:10.1109/28.821794 · Cited by 9 · see citing works
Self-citationFast detection technique for voltage unbalance in three-phase power system
Al‐Naimi, I., Ghaeb, J. A., Baniyounis, M. J., & Al-Khawaldeh, M. A. (2021) · International Journal of Power Electronics and Drive Systems/International Journal of Electrical and Computer Engineering · doi:10.11591/ijpeds.v12.i4.pp2230-2242 · Cited by 9 · see citing works
Agamloh, E. B., Peele, S., & Grappe, J. (2012) · IEEE Conference record of annual Pulp and Paper Industry Technical Conference · doi:10.1109/ppic.2012.6293004 · Cited by 9 · see citing works
Singh, R. R., Selvaraj, R., Mohan, H., & Chelliah, T. R. (2018) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2018.2833798 · Cited by 9 · see citing works
Al-Badri, M., Pillay, P., & Angers, P. (2015) · IEEE International Electric Machines & Drives Conference (IEMDC) · doi:10.1109/iemdc.2015.7409033 · Cited by 8 · see citing works
Temiz, I., Aküner, M. C., & ÇALIK, H. (2011) · Elektronika ir Elektrotechnika · doi:10.5755/j01.eee.109.3.167 · Cited by 7 · see citing works
Assessment of disturbed voltage supply effects on steady-state performance of an induction motor
Mohammed, J. A.-K., Al-Sakini, S. R., & Hussein, A. A. (2020) · International Journal of Electrical and Computer Engineering (IJECE) · doi:10.11591/ijece.v10i3.pp2259-2270 · Cited by 7 · see citing works
Revision of Concepts and Approaches for Unbalance Problems in Distribution
Reineri, C., Zapata, J. C. G., Belenguer, E., & Felici, M. (2006) · IEEE PES Transmission & Distribution Conference and Exposition - Latin America (PES T&D-LA) · doi:10.1109/tdcla.2006.311575 · Cited by 7 · see citing works
Wang, L., & Liu, L.-S. (2002) · IEEE Power Engineering Society Winter Meeting · doi:10.1109/pesw.2000.849979 · Cited by 6 · see citing works
Aree, P. (2016) · International Conference on Electrical Engineering/Electronics, Computer, Telecommunications and Information Technology (ECTI-CON) · doi:10.1109/ecticon.2016.7561443 · Cited by 6 · see citing works
The impact of supply phase shift on the three phase induction motor operation
Adekitan, A. I., Ogunjuyigbe, A. S. O., & Ayodele, T. R. (2019) · Engineering review · doi:10.30765/er.39.3.08 · Cited by 6 · see citing works
Increasing the required slip range of wound induction generator in wind power systems
Dalabeeh, A., Al–Mofleh, A., Younes, T. M., Al-Rawashdeh, A. Y., & Hindi, A. T. (2020) · Bulletin of Electrical Engineering and Informatics · doi:10.11591/eei.v9i2.1795 · Cited by 6 · see citing works
Accurate steady-state performance assessment of three-phase induction motor using NEMA definition
Singh, S. B., Singh, A. K., & Thakur, P. (2014) · International Conference on Harmonics and Quality of Power · doi:10.1109/ichqp.2014.6842803 · Cited by 6 · see citing works
Power Conditioning With Intelligent Control Using a Novel Recursive Stochastic Optimization
Hamici, Z. M., & Elhaija, W. A. (2018) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2856195 · Cited by 6 · see citing works
Steady-state phase-coordinate model for induction machines
Hoadley, D., Moorthy, S., & Al-Dabbagh, M. (2001) · Electric Power Systems Research · doi:10.1016/s0378-7796(01)00079-7 · Cited by 5 · see citing works
A virtual instrument for the measurement of voltage unbalance in power systems
Barros, J., Diego, R. I., & de Apráiz, M. (2008) · International Conference on Electrical Machines (ICEM) · doi:10.1109/icelmach.2008.4800050 · Cited by 5 · see citing works
Deleanu, S., Lipinski, G. V., Iordache, M., Stănculescu, M., & Niculae, D. (2019) · International Conference on Modern Power Systems (MPS) · doi:10.1109/mps.2019.8759684 · Cited by 5 · see citing works
Precise assessment of induction motor performance based on NEMA definition
Singh, S. B., & Singh, A. K. (2013) · International Conference on Power, Energy and Control · doi:10.1109/icpec.2013.6527707 · Cited by 4 · see citing works
Faiz, J., Ebrahimi, B. M., Ghofrani, M., Rajabioun, R., & Farazmand, A. (2011) · Electromagnetics · doi:10.1080/02726343.2011.537935 · Cited by 4 · see citing works
Magnetization-Dependent Core-Loss Model in a Three-Phase Self-Excited Induction Generator
Al-Senaidi, S. H., Alolah, A. I., & Alkanhal, M. A. S. (2018) · Energies · doi:10.3390/en11113228 · Cited by 4 · see citing works
Causes and effects of single-phasing induction motors
Kersting, W. H. (2004) · Rural Electric Power Conference · doi:10.1109/repcon.2004.1307038 · Cited by 4 · see citing works
Self-citationFast correction of voltage unbalance factor in three-phase power system using neural network
Ghaeb, J. A., Ragab, D. M., & Al‐Naimi, I. (2018) · International Symposium on Mechatronics and its Applications · doi:10.1109/isma.2018.8330136 · Cited by 4 · see citing works
Peñalba, L. F. M. (2007) · Electrical Engineering · doi:10.1007/s00202-007-0089-8 · Cited by 4 · see citing works
The effects of voltage and winding abnormalities on the measured performance of induction motors
Wallace, A. K., von Jouanne, A., Andrews, P. S., Wohlgemuth, C., & Wainwright, G. (2002) · IEEE Industry Applications Society Annual Meeting (IAS) · doi:10.1109/ias.1997.643027 · Cited by 4 · see citing works
Convergence of Distributed Steinmetz Control for Balancing Distribution Network Voltages
Geng, S., & Hiskens, I. A. (2021) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2021.3134185 · Cited by 3 · see citing works
Performance of Induction Motor Under the Effect of Voltage Unbalance with Loading Consideration
Dekhandji, F. Z., & Refoufi, L. (2015) · Springer eBooks · doi:10.1007/978-3-319-17031-2_49 · Cited by 3 · see citing works
Phase Shift-Based Fault Detection of Induction Motor Using IoT System
Chaihang, S., Chamnongwai, N., & Chansri, P. (2022) · International Conference on Power, Energy and Innovations (ICPEI) · doi:10.1109/icpei55293.2022.9986538 · Cited by 3 · see citing works
Thermal effect of unbalanced voltage conditions in induction motor by FEM
Kraikitrat, K., & Ruangsinchaiwanich, S. (2011) · International Conference on Electrical Machines and Systems (ICEMS) · doi:10.1109/icems.2011.6073459 · Cited by 3 · see citing works
Unbalance Detection in Electrical Engines Using an In-Line Fiber Etalon
Corres, J. M., Bravo, J. A., Arregui, F. J., & Matias, I. R. (2005) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/icsens.2005.1597957 · Cited by 3 · see citing works
Investigating the effects of faulty induction machine in distribution systems
Momoh, O. D., Ajewole, T. O., & Sadiku, M. N. O. (2020) · Scientific African · doi:10.1016/j.sciaf.2020.e00486 · Cited by 3 · see citing works
Analysis of four wire delta center tappped transformer connections
Kersting, W. H. (2005) · IEEE Power Engineering Society General Meeting · doi:10.1109/pes.2005.1489076 · Cited by 3 · see citing works
Self-citationJu, Y., Qi, Z., Ye, L., Zheng, J., & Yang, Y. J. (2017) · IEEE Conference on Energy Internet and Energy System Integration (EI2) · doi:10.1109/ei2.2017.8245730 · Cited by 2 · see citing works
Kersting, W. H., & Rathbun, J. S. (2003) · Rural Electric Power Conference · doi:10.1109/repcon.1999.768692 · Cited by 2 · see citing works
Self-citationModel for evaluating the electric power output of Pressure Retarded Osmosis generation plants
Llamas-Rivas, M., Pizano-Martínez, A., Fuerte-Esquivel, C. R., Merchan‐Villalba, L. R., & Gutiérrez-Martínez, V. J. (2020) · International Marine Energy Journal · doi:10.36688/imej.3.1-10 · Cited by 2 · see citing works
Cuong, N. X., Nhu, Y., & Hieu, T. Q. (2020) · Inżynieria Mineralna · doi:10.29227/im-2020-02-18 · Cited by 2 · see citing works
Silva, M. D. D. C. E., Filho, A. D. L. F., & Abada, C. C. (2016) · International Conference on Harmonics and Quality of Power · doi:10.1109/ichqp.2016.7783396 · Cited by 2 · see citing works
Modeling of Doubly Fed Induction Generators for Distribution System Power Flow Analysis
Dadhania, A. (2021) · doi:10.32920/ryerson.14644032 · Cited by 2 · see citing works
Elhaija, W. A., & Hamici, Z. M. (2020) · Electric Power Components and Systems · doi:10.1080/15325008.2020.1821839 · Cited by 1 · see citing works
Kersting, W. H. (2016) · CRC Press eBooks · doi:10.1201/b11697-13 · Cited by 1 · see citing works
Self-citationModeling induction machines and core-form transformers in unbalanced distribution circuits
Amber, L., Ortmeyer, T. H., & McGrath, P. B. (2014) · IEEE Power Engineering Society General Meeting · doi:10.1109/pesgm.2014.6938920 · Cited by 1 · see citing works
- Authors
- Kersting, W. H., & Phillips, W. H.
- Affiliations
- New Mexico State University (US)
- ORCID
- Kersting, W.H.
- Venue
- IEEE Transactions on Industry Applications
- Published
- 1997
- Volume
- 33
- Issue
- 2
- Pages
- 415-420
- ISSN
- 0093-9994 (ISSN-L)
- OpenAlex
- W4250412834
- Cited by
- 109
- References
- 3
- Citations by year
- 2024: 2 · 2023: 2 · 2022: 2 · 2021: 7 · 2020: 7 · 2019: 3 · 2018: 5 · 2017: 6 · 2016: 5 · 2015: 4 · 2014: 4 · 2013: 3 · 2012: 3
- FWCI
- 1.50
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Industry Applications (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electric Motor Design and Analysis
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Power Quality and Harmonics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electric Power Systems and Control
- Keywords
- voltage unbalance, three-phase induction motor, motor heating, symmetrical components
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review