CoChat

Plasma formation in water by picosecond and nanosecond Nd:YAG laser pulses. II. Transmission, scattering, and reflection

Nahen, K., Vogel, A. · 1996 · IEEE Journal of Selected Topics in Quantum Electronics
Cited by 86

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

For pt.I see ibid., vol.2, no.4, p.847-60 (1996) We investigated the transmission, scattering, and reflection of plasmas produced in water by Nd:YAG laser pulses of 6-ns and 30-ps duration. The transmission measurements comprise a large energy range at wavelengths of 1064 and 532 nm and various focusing angles between 1.7/spl deg/ and 22/spl deg/. This parameter range covers the parameters used for intraocular microsurgery, but also allows one to assess the influence of self-focusing on plasma shielding, which is only relevant at small focusing angles. We found that most of the laser light is either absorbed or transmitted; scattering and reflection amount to only a few percent of the incident laser energy. The transmission is considerably higher for picosecond pulses than for nanosecond pulses, regardless of the focusing angle. The plasma transmission increases with decreasing focusing angle. Self-focusing, which occurs at focusing angles below 2/spl deg/, leads to a further increase of transmission. The experimental results were compared with the predictions of the moving breakdown distributed shielding model. Only partial agreement could be achieved, because the model assumes a spatially and temporally constant absorption coefficient within the plasma which is not realistic. The model can, however, be used to determine the average absorption coefficient. Fits of calculated transmission curves to the experimental data at /spl theta/=22/spl deg/ yielded 900 cm/sup -1//spl les//spl alpha//spl les/1800 cm/sup -1/ nanosecond plasmas and 360 cm/sup -1//spl les//spl alpha//spl les/570 cm/sup -1/ picosecond plasmas. The efficacy of plasma-mediated intraocular laser surgery is higher with 6-ns pulses than with 30-ps pulses, because with the nanosecond pulses nearly 50% of the laser pulse energy is absorbed already at threshold, whereas it is only 8% with the picosecond pulses.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/2944.577308

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 86

Metadata

Authors
Nahen, K., & Vogel, A.
Venue
IEEE Journal of Selected Topics in Quantum Electronics
Published
1996
Volume
2
Issue
4
Pages
861-871
ISSN
1077-260X (ISSN-L)
OpenAlex
W2159004054
Cited by
86
References
2
FWCI
6.16
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.