Cited by 437Muscle activation and electromyography studiesProsthetics and Rehabilitation RoboticsEEG and Brain-Computer Interfaces

A myosignal-based powered exoskeleton system

Rosen, J., Brand, M., Fuchs, M.B., Arcan, M.·2001·IEEE Transactions on Systems, Man, and Cybernetics - Part A: Systems and Humans

Abstract

This paper studies the integration of a human arm with a powered exoskeleton (orthotic device) and its experimental implementation in an elbow joint, naturally controlled by the human. The human-machine interface was set at the neuromuscular level, by using the neuromuscular signal (EMG) as the primary command signal for the exoskeleton system. The EMG signal along with the joint kinematics were fed into a myoprocessor which in turn predicted the muscle moments on the elbow joint. The moment-based control system integrated myoprocessor moment prediction with feedback moments measured at the human arm/exoskeleton and external load/exoskeleton interfaces. The exoskeleton structure under study was a two-link, two-joint mechanism, corresponding to the arm limbs and joints, which was mechanically linked by the human operator. Four indices of performance were used to define the quality of the human/machine integration and to evaluate the operational envelope of the system. Experimental results indicate the feasibility of an EMG-based power exoskeleton system as an integrated human-machine system using high-level neurological signals.

Integrity signals

Registry

Crossref · 10.1109/3468.925661

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Using this myoprocessor scheme, a one-degree-of-freedom exoskeleton was controlled using dynamic, kinematic, and physiological feedback.

    “Using this schemea one-degree-of-freedom exoskeleton has been controlled using a multiple-feedback approach: (1) dynamic feedback - the moments generated at the interfaces between the human arm, the external load, and the exoskeleton structure; (2) kinematic feedback -the joint angular trajectories recorded using encoders, and the angular velocity and acceleration calculated by finite differences;”
  • Experimental tests have shown that use of sEMG significantly improved the mechanical gain of the system while maintaining natural control.

    “Experimental tests have shown that the use of sEMG significantly improved the mechanical gain of the system (i.e., the possibility of augmenting capabilities and/or reducing human muscular efforts to carry out the different tasks) while maintaining natural control of the system.”
  • Rosen et al. developed a myoprocessor based on the Hill model of muscular activation to extract force/torque information from muscle information.

    “Rosen et al. (2001) developed a 'myoprocessor' based on the Hill model of muscular activation to extract force/torque information from muscle information.”

No citation lists for this paper

No citation lists for this paper yet — checked again daily.

References 45 · Cited by 437

Authors
Rosen, J., Brand, M., Fuchs, M. B., & Arcan, M.
Affiliations
Tel Aviv University (IL)
Venue
IEEE Transactions on Systems, Man, and Cybernetics - Part A: Systems and Humans
Published
2001-05
Volume
31
Issue
3
Pages
210-222
ISSN
1083-4427 (ISSN-L)
OpenAlex
W2168117107
Cited by
437
References
45
Citations by year
2026: 3 · 2025: 13 · 2024: 13 · 2023: 14 · 2022: 18 · 2021: 18 · 2020: 21 · 2019: 29 · 2018: 24 · 2017: 30 · 2016: 29 · 2015: 16 · 2014: 21 · 2013: 25 · 2012: 18
FWCI
4.77
Type
journal article
Language
en
Open access
closed
Locations
IEEE Transactions on Systems Man and Cybernetics - Part A Systems and Humans (publishedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
  • Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
  • Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
Keywords
powered exoskeleton, electromyography, elbow, human-machine interaction, neuromuscular control, orthoses, human-machine integration

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›