The DOI matches its Crossref record.
The strategic power infrastructure defense (SPID) system. A conceptual design
Abstract
A power system can become vulnerable for various reasons, these sources of vulnerability are either internal or external to the infrastructure that comprises the power system. Threats from vulnerability sources that are internal to the civil infrastructure may be reduced by decreasing the probability and severity of occurrence through the improved engineering of related systems. On the other hand, threats from vulnerability sources that are external to the infrastructure may be reduced by decreasing the severity of occurrence. To prevent or reduce catastrophic failures and cascading sequences of events caused by the various sources of vulnerability, the Advanced Power Technologies Consortium is researching ways to revolutionize defense strategies and technologies that will significantly reduce the vulnerability of the power infrastructure. Our vision is a wide-area, intelligent, adaptive protection and control system that empowers future grids by providing critical and extensive information in real time, assessing system vulnerability quickly, and performing timely self-healing and adaptive reconfiguration actions based on system-wide analysis. The proposed system is referred to as the strategic power infrastructure defense (SPID) system. The article discusses the conceptual design of the SPID system and the associated technical challenges. The fundamentally important concept is that the SPID system provides self-healing and adaptive reconfiguration capabilities for power grids based on wide-area system vulnerability assessment. Some experts believe that if 0.4% of the load had been shed for 30 minutes, the widespread power outage in the Western United States on 10 August 1996 could have been avoided. The SPID is intended to identify such load-shedding actions in real time based on proposed vulnerability assessment and protection/control systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Power System Control Centers: Past, Present, and Future
Wu, F. F., Moslehi, K., & Bose, A. (2005) · Proceedings of the IEEE · doi:10.1109/jproc.2005.857499 · Cited by 473
Baldick, R., Chowdhury, B., Dobson, I., Dong, Z., Gou, B., Hawkins, D., Huang, H., Joung, M., Kirschen, D., Li, F., et al. (2008) · 2008 IEEE Power and Energy Society General Meeting - Conversion and Delivery of Electrical Energy in the 21st Century · doi:10.1109/pes.2008.4596430 · Cited by 318
Glavic, M. (2019) · Annual Reviews in Control · doi:10.1016/j.arcontrol.2019.09.008 · Cited by 163
An intrusion and defense testbed in a cyber-power system environment
Hong, J., Wu, S.-S., Stefanov, A., Fshosha, A., Liu, C.-C., Gladyshev, P., & Govindarasu, M. (2011) · 2011 IEEE Power and Energy Society General Meeting · doi:10.1109/pes.2011.6039375 · Cited by 47
Self-citation
Metadata
- Venue
- IEEE Control Systems
- Published
- 2000-08
- Volume
- 20
- Issue
- 4
- Pages
- 40-52
- ISSN
- 1066-033X (ISSN-L)
- 1941-000X
- OpenAlex
- W2016678165
- Cited by
- 202
- References
- 0
- FWCI
- 6.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.