The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Simple, Accurate, and Robust Projector-Camera Calibration
Abstract
Structured-light systems are simple and effective tools to acquire 3D models. Built with off-the-shelf components, a data projector and a camera, they are easy to deploy and compare in precision with expensive laser scanners. But such a high precision is only possible if camera and projector are both accurately calibrated. Robust calibration methods are well established for cameras but, while cameras and projectors can both be described with the same mathematical model, it is not clear how to adapt these methods to projectors. In consequence, many of the proposed projector calibration techniques make use of a simplified model, neglecting lens distortion, resulting in loss of precision. In this paper, we present a novel method to estimate the image coordinates of 3D points in the projector image plane. The method relies on an uncalibrated camera and makes use of local homographies to reach sub-pixel precision. As a result, any camera model can be used to describe the projector, including the extended pinhole model with radial and tangential distortion coefficients, or even those with more complex lens distortion models.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A flexible new technique for camera calibration
Zhang, Z. (2000) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.888718 · Cited by 15,004
Bradski, G. R. (2000) · Medical Entomology and Zoology · Cited by 5,994
Novel method for structured light system calibration
Huang, P. S. (2006) · Optical Engineering · doi:10.1117/1.2336196 · Cited by 760
SSD: Smooth Signed Distance Surface Reconstruction
Calakli, F., & Taubin, G. (2011) · Computer Graphics Forum · doi:10.1111/j.1467-8659.2011.02058.x · Cited by 220
Self-citationA user-friendly method to geometrically calibrate projector-camera systems
Audet, S., & Okutomi, M. (2009) · 2009 IEEE Computer Society Conference on Computer Vision and Pattern Recognition Workshops · doi:10.1109/cvprw.2009.5204319 · Cited by 92
A practical structured light acquisition system for point-based geometry and texture
Sadlo, F., Weyrich, T., Peikert, R., & Groß, M. H. (2005) · UCL Discovery (University College London) · Cited by 66
Robust pixel classification for 3D modeling with structured light
Xu, Y., & Aliaga, D. G. (2007) · Proceedings · doi:10.1145/1268517.1268556 · Cited by 41
Calibration for high-definition camera rigs with marker chessboard
Chen, J., Benzeroual, K., & Allison, R. S. (2012) · 2009 IEEE Computer Society Conference on Computer Vision and Pattern Recognition Workshops · doi:10.1109/cvprw.2012.6238905 · Cited by 19
SSD-C: Smooth Signed Distance Colored Surface Reconstruction
Calakli, F., & Taubin, G. (2012) · Springer eBooks · doi:10.1007/978-1-4471-2804-5_18 · Cited by 16
Self-citation
Cited by
Phase shifting algorithms for fringe projection profilometry: A review
Zuo, C., Feng, S., Huang, L., Tao, T., Yin, W., & Chen, Q. (2018) · Optics and Lasers in Engineering · doi:10.1016/j.optlaseng.2018.04.019 · Cited by 1,291
Calibration of fringe projection profilometry: A comparative review
Feng, S., Zuo, C., Zhang, L., Tao, T., Hu, Y., Yin, W., Qian, J., & Chen, Q. (2021) · Optics and Lasers in Engineering · doi:10.1016/j.optlaseng.2021.106622 · Cited by 347
Metadata
- Authors
- Moreno, D., & Taubin, G.
- Venue
- 2012 Second International Conference on 3D Imaging, Modeling, Processing, Visualization & Transmission
- Publisher
- IEEE
- Published
- 2012-10
- Pages
- 464-471
- OpenAlex
- W2171988673
- Cited by
- 317
- References
- 9
- FWCI
- 9.12
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.