The DOI matches its Crossref record; 72 of the 72 references it cites were found in a registry or an index.
Calibration of fringe projection profilometry: A comparative review
Open accessAbstract
Fringe projection profilometry is widely used for three-dimensional (3D) measurements. System calibration is crucial to fringe projection systems, since it determines how the phase is converted into 3D geometry. Many methods and studies on calibration have been presented in the last few years. However, a comparative overview on the accuracy and the implementation details is still lacking. In this work, we present a review of some of the most used calibration methods. First, the basic principles are reviewed. Then, both quantitative and qualitative comparative experiments are implemented to show the advantages and constraints of each method. Further, a number of factors that may affect the performance of the calibration are discussed. Sample codes are available for better comprehension and a quick start of these methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A flexible new technique for camera calibration
Zhang, Z. (2000) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.888718 · Cited by 15,004
(2016) · Cited by 11,679
A Taxonomy and Evaluation of Dense Two-Frame Stereo Correspondence Algorithms
Scharstein, D., & Szeliski, R. (2002) · International Journal of Computer Vision · doi:10.1023/a:1014573219977 · Cited by 6,740
Tsai, R. (1987) · IEEE Journal on Robotics and Automation · doi:10.1109/jra.1987.1087109 · Cited by 5,838
Deep learning for computer vision: A brief review
Voulodimos, A., Doulamis, N., Doulamis, A., & Protopapadakis, E. (2018) · Computational Intelligence and Neuroscience · doi:10.1155/2018/7068349 · Cited by 3,403
Two-dimensional digital image correlation for in-plane displacement and strain measurement: a review
Pan, B., Qian, K., Xie, H., & Asundi, A. (2009) · Measurement Science and Technology · doi:10.1088/0957-0233/20/6/062001 · Cited by 3,166
A four-step camera calibration procedure with implicit image correction
Heikkila, J., & Silven, O. (2002) · Proceedings of IEEE Computer Society Conference on Computer Vision and Pattern Recognition · doi:10.1109/cvpr.1997.609468 · Cited by 2,051
Fourier transform profilometry for the automatic measurement of 3-D object shapes
Takeda, M., & Mutoh, K. (1983) · Applied Optics · doi:10.1364/ao.22.003977 · Cited by 1,855
Overview of three-dimensional shape measurement using optical methods
Brown, G. M. (2000) · Optical Engineering · doi:10.1117/1.602438 · Cited by 1,327
Metadata
- Authors
- Feng, S., Zuo, C., Zhang, L., Tao, T., Hu, Y., Yin, W., Qian, J., & Chen, Q.
- Venue
- Optics and Lasers in Engineering
- Publisher
- Elsevier BV
- Published
- 2021-08
- Volume
- 143
- Pages
- 106622
- ISSN
- 0143-8166 (ISSN-L)
- OpenAlex
- W3140963551
- Cited by
- 347
- References
- 72
- FWCI
- 19.93
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Calibration of fringe projection profilometry: A comparative review. https://app.cochat.ai/papers/10.1016/j.optlaseng.2021.106622
- The paper
- Feng, S., Zuo, C., Zhang, L., Tao, T., Hu, Y., Yin, W., Qian, J., & Chen, Q. (2021). Calibration of fringe projection profilometry: A comparative review. Optics and Lasers in Engineering. https://doi.org/10.1016/j.optlaseng.2021.106622
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.