The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
The discontinuous conduction mode Sepic and Cuk power factor preregulators: analysis and design
Open accessAbstract
Sepic and Cuk power converters working as power factor preregulators (PFP) in the discontinuous conduction mode (DCM) present the following desirable characteristics for a PFP: (1) the power converter works as a voltage follower (no current loop is needed); (2) the theoretical power factor is unity; and (3) the input current ripple is defined at the design stage. Besides, input-output galvanic isolation is easily obtained. This paper analyzes the operation of both power converters as DCM-PFP. Design equations are derived, as well as a small-signal model to aid the control loop design. Both simulation and experimental results are presented that are in agreement with the theoretical analysis and complement the work.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Input filter considerations in design and application of switching regulators.
Middlebrook, R. D. (1976) · Medical Entomology and Zoology · Cited by 1,180
Design and analysis of a hysteretic boost power factor correction circuit
Zhou, C., Ridley, R. B., & Lee, F. C. (2002) · 21st Annual IEEE Conference on Power Electronics Specialists · doi:10.1109/pesc.1990.131271 · Cited by 167
Sebastián, J., Uceda, J., Cobos, J. A., Arau, J., & Aldana, F. (2002) · IEEE Power Electronics Specialists Conference (PESC) · doi:10.1109/pesc.1991.162764 · Cited by 111
Self-citation
Cited by
Bridgeless SEPIC PFC Rectifier With Reduced Components and Conduction Losses
Mahdavi, M., & Farzanehfard, H. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2095393 · Cited by 285
Bridgeless SEPIC Rectifier With Unity Power Factor and Reduced Conduction Losses
Ismail, E. H. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2007552 · Cited by 255
Digital control of isolated Cuk power factor correction converter under wide range of load variation
Dian, S., Wen, X., Deng, X., & Zhang, S. (2015) · IET Power Electronics · doi:10.1049/iet-pel.2014.0111 · Cited by 45
Tibola, G., & Barbi, I. (2011) · 2011 IEEE International Symposium of Circuits and Systems (ISCAS) · doi:10.1109/iscas.2011.5938180 · Cited by 9
“expression confirms that the three-phase system is equivalent to three single-phase systems connected in parallel, as discussed in [17].”
Background
Metadata
- Authors
- Simonetti, D. S. L., Sebastion, J., & Uceda, J.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 1997
- Volume
- 44
- Issue
- 5
- Pages
- 630-637
- ISSN
- 0278-0046 (ISSN-L)
- OpenAlex
- W2153504292
- Cited by
- 381
- References
- 3
- FWCI
- 2.01
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.