The DOI matches its Crossref record.
Dual current control scheme for PWM converter under unbalanced input voltage conditions
Abstract
Voltage unbalance in a three-phase system causes performance deterioration of PWM power converters by producing 120 Hz voltage ripples in the DC link and by increasing the reactive power. To eliminate the DC link voltage ripple and the DC component of the reactive power, both positive- and negative-sequence currents should be controlled simultaneously, according to the paper by Rioual et al (1996). The authors used two synchronous reference frames: a positive-sequence current regulated by a proportional integral (PI) controller in a positive synchronous reference frame (SRF); and a negative-sequence current regulated by a PI controller in a negative SRF. In the positive SRF, which rotates counterclockwise, the positive sequence appears as DC, while the negative sequence appears as 120 Hz. In contrast, in the negative SRF, which rotates clockwise, the negative sequence appears as DC, while the positive sequence appears as 120 Hz. By deleting 120 Hz components using a notch filter in each SRF, one can measure positive- and negative-sequence currents separately, and use them for constructing two feedback controllers. Since the negative-sequence current is also controlled in its own SRF by a DC command, this approach yields better performance without increasing the control gain. Note that, since the controller is implemented by a software routine in the digital signal professor chip, using two SRFs does not require additional hardware. The authors demonstrated the effectiveness of the proposed control scheme by using computer simulation and experiments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A Review of Three-Phase Improved Power Quality AC–DC Converters
Singh, B., Singh, B. N., Chandra, A., Al-Haddad, K., Pandey, A., & Kothari, D. P. (2004) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2004.825341 · Cited by 1,728
Safayatullah, M., Elrais, M. T., Ghosh, S., Rezaii, R., & Batarseh, I. (2022) · IEEE Access · doi:10.1109/access.2022.3166935 · Cited by 615
Guan, M., & Xu, Z. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2192752 · Cited by 549
Camacho, A., Castilla, M., Miret, J., Borrell, A., & de Vicuna, L. G. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2347266 · Cited by 300
A Cooperative Imbalance Compensation Method for Distributed-Generation Interface Converters
Cheng, P.-T., Chen, C.-A., Lee, T.-L., & Kuo, S.-Y. (2009) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2009.2013601 · Cited by 253
Metadata
- Authors
- Song, H.-S., & Nam, K.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 1999
- Volume
- 46
- Issue
- 5
- Pages
- 953-959
- ISSN
- 0278-0046 (ISSN-L)
- OpenAlex
- W2143489520
- Cited by
- 930
- References
- 0
- FWCI
- 4.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Dual current control scheme for PWM converter under unbalanced input voltage conditions. https://app.cochat.ai/papers/10.1109/41.793344
- The paper
- Song, H.-S., & Nam, K. (1999). Dual current control scheme for PWM converter under unbalanced input voltage conditions. IEEE Transactions on Industrial Electronics. https://doi.org/10.1109/41.793344
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.