Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 277

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

A homogeneity correction method for magnetic resonance imaging with time-varying gradients

Noll, D.C., Meyer, C.H., Pauly, J.M., Nishimura, D.G., Macovski, A.·1991·IEEE Transactions on Medical Imaging

Abstract

When time-varying gradients are used for imaging, the off-resonance behavior does not just cause geometric distortion as is the case with spin-warp imaging, but changes the shape of the impulse response and causes blurring. This effect is well known for projection reconstruction and spiral k-space scanning sequences. The authors introduce a reconstruction and homogeneity correction method to correct for the zeroth order effects of inhomogeneity using prior knowledge of the inhomogeneity. In this method, the data are segmented according to collection time, reconstructed using some fast, linear algorithm, correlated for inhomogeneity, and then superimposed to yield a homogeneity corrected image. This segmented method is compared to a conjugate phase reconstruction in terms of degree of correction and execution time. The authors apply this method to in vivo images using projection-reconstruction and spiral-scan sequences.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/42.108599

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Research works printed but not linked: 13

  1. 10.1109/42.3926 · doi:10.1109/42.3926
  2. 10.1109/TMI.1985.4307716 · doi:10.1109/tmi.1985.4307716
  3. 10.1109/TMI.1987.4307794 · doi:10.1109/tmi.1987.4307794
  4. 10.1109/TMI.1985.4307722 · doi:10.1109/tmi.1985.4307722
  5. 10.1088/0022-3735/15/10/031 · doi:10.1088/0022-3735/15/10/031
  6. 10.1118/1.595989 · doi:10.1118/1.595989
  7. jackson, 1990, Projection reconstruction with a twist, ? roc 9 th Annu Mtg Soc Magn Res Med, 428
  8. 10.1148/radiology.179.3.2027991 · doi:10.1148/radiology.179.3.2027991
  9. pauly, 1989, Slice-selective excitation for very short T<subscript>2</subscript> species, ?roc 6th Annu Mtg Soc Mag Res Med, 28
  10. nishimura, 1990, MR angiography using projection-reconstruction imaging, Magn Reson lmag, 8 s1, 107
  11. 10.1118/1.595732 · doi:10.1118/1.595732
  12. meyer, 1987, Square spiral fast imaging: interleaving and off-resonance effects, ?roc 6th Annu Mtg Soc Mag Res Med, 230
  13. meyer, 1990, A comparison of fast spiral sequences for cardiac imaging and angiography, Proc Annu Mtg Soc Magn Reson Med, 403

Cited by

See all 277

Metadata

Authors
Noll, D. C., Meyer, C. H., Pauly, J. M., Nishimura, D. G., & Macovski, A.
Venue
IEEE Transactions on Medical Imaging
Published
1991
Volume
10
Issue
4
Pages
629-637
ISSN
0278-0062 (ISSN-L)
OpenAlex
W2134879150
Cited by
277
References
9
FWCI
2.50
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A homogeneity correction method for magnetic resonance imaging with time-varying gradients. https://app.cochat.ai/papers/10.1109/42.108599
The paper
Noll, D. C., Meyer, C. H., Pauly, J. M., Nishimura, D. G., & Macovski, A. (1991). A homogeneity correction method for magnetic resonance imaging with time-varying gradients. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/42.108599

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.