A homogeneity correction method for magnetic resonance imaging with time-varying gradients
Abstract
When time-varying gradients are used for imaging, the off-resonance behavior does not just cause geometric distortion as is the case with spin-warp imaging, but changes the shape of the impulse response and causes blurring. This effect is well known for projection reconstruction and spiral k-space scanning sequences. The authors introduce a reconstruction and homogeneity correction method to correct for the zeroth order effects of inhomogeneity using prior knowledge of the inhomogeneity. In this method, the data are segmented according to collection time, reconstructed using some fast, linear algorithm, correlated for inhomogeneity, and then superimposed to yield a homogeneity corrected image. This segmented method is compared to a conjugate phase reconstruction in terms of degree of correction and execution time. The authors apply this method to in vivo images using projection-reconstruction and spiral-scan sequences.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Image Formation by Induced Local Interactions: Examples Employing Nuclear Magnetic Resonance
LAUTERBUR, P. C. (1973) · Nature · doi:10.1038/242190a0 · Cited by 3,611
Image Reconstruction from Projections
(2004) · Biomedical Engineering · doi:10.1201/9780203492543.ch9 · Cited by 915
Spin warp NMR imaging and applications to human whole-body imaging
Edelstein, W. A., Hutchison, J. M. S., Johnson, G., & Redpath, T. (1980) · Physics in Medicine & Biology · doi:10.1088/0031-9155/25/4/017 · Cited by 803
Simultaneous spatial and spectral selective excitation
Meyer, C. H., Pauly, J. M., Macovskiand, A., & Nishimura, D. G. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910150211 · Cited by 498
Self-citationHigh-Speed Spiral-Scan Echo Planar NMR Imaging-I
Ahn, C. B., Kim, J. H., & Cho, Z. H. (1986) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1986.4307732 · Cited by 487
Ernst, R. R. (2011) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2011.08.006 · Cited by 314
Kumar, A., Welti, D., & Ernst, R. R. (1975) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(75)90224-3 · Cited by 311
Volumetric NMR imaging with time‐varying gradients
Macovski, A. (1985) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910020105 · Cited by 121
Self-citationSpiral Sampling in Magnetic Resonance Imaging-The Effect of Inhomogeneities
Yudilevich, E., & Stark, H. (1987) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1987.4307852 · Cited by 73
Research works printed but not linked: 13
- 10.1109/42.3926 · doi:10.1109/42.3926
- 10.1109/TMI.1985.4307716 · doi:10.1109/tmi.1985.4307716
- 10.1109/TMI.1987.4307794 · doi:10.1109/tmi.1987.4307794
- 10.1109/TMI.1985.4307722 · doi:10.1109/tmi.1985.4307722
- 10.1088/0022-3735/15/10/031 · doi:10.1088/0022-3735/15/10/031
- 10.1118/1.595989 · doi:10.1118/1.595989
- jackson, 1990, Projection reconstruction with a twist, ? roc 9 th Annu Mtg Soc Magn Res Med, 428
- 10.1148/radiology.179.3.2027991 · doi:10.1148/radiology.179.3.2027991
- pauly, 1989, Slice-selective excitation for very short T<subscript>2</subscript> species, ?roc 6th Annu Mtg Soc Mag Res Med, 28
- nishimura, 1990, MR angiography using projection-reconstruction imaging, Magn Reson lmag, 8 s1, 107
- 10.1118/1.595732 · doi:10.1118/1.595732
- meyer, 1987, Square spiral fast imaging: interleaving and off-resonance effects, ?roc 6th Annu Mtg Soc Mag Res Med, 230
- meyer, 1990, A comparison of fast spiral sequences for cardiac imaging and angiography, Proc Annu Mtg Soc Magn Reson Med, 403
Cited by
Advances in sensitivity encoding with arbitrary k‐space trajectories
Pruessmann, K. P., Weiger, M., Börnert, P., & Boesiger, P. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1241 · Cited by 1,211
Fast Spiral Coronary Artery Imaging
Meyer, C. H., Hu, B. S., Nishimura, D. G., & Macovski, A. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910280204 · Cited by 866
Self-citationFast, iterative image reconstruction for MRI in the presence of field inhomogeneities
Sutton, B. P., Noll, D. C., & Fessler, J. A. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.808360 · Cited by 397
Self-citationAltered resting-state amygdala functional connectivity in men with posttraumatic stress disorder
Sripada, R. K., King, A. P., Garfinkel, S. N., Wang, X., Sripada, C. S., Welsh, R. C., & Liberzon, I. (2012) · Journal of Psychiatry and Neuroscience · doi:10.1503/jpn.110069 · Cited by 352
Design and analysis of a practical 3D cones trajectory
Gurney, P. T., Hargreaves, B. A., & Nishimura, D. G. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20796 · Cited by 335
Self-citation
Metadata
- Authors
- Noll, D. C., Meyer, C. H., Pauly, J. M., Nishimura, D. G., & Macovski, A.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 1991
- Volume
- 10
- Issue
- 4
- Pages
- 629-637
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2134879150
- Cited by
- 277
- References
- 9
- FWCI
- 2.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A homogeneity correction method for magnetic resonance imaging with time-varying gradients. https://app.cochat.ai/papers/10.1109/42.108599
- The paper
- Noll, D. C., Meyer, C. H., Pauly, J. M., Nishimura, D. G., & Macovski, A. (1991). A homogeneity correction method for magnetic resonance imaging with time-varying gradients. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/42.108599
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.