Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 335

The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.

Design and analysis of a practical 3D cones trajectory

Open access
Gurney, Paul T., Hargreaves, Brian A., Nishimura, Dwight G.·2006·Magnetic Resonance in Medicine

Abstract

The 3D Cones k‐space trajectory has many desirable properties for rapid and ultra‐short echo time magnetic resonance imaging. An algorithm is presented that generates the 3D Cones gradient waveforms given a desired field of view and resolution. The algorithm enables a favorable trade‐off between increases in readout time and decreases in the total number of required readouts. The resulting trajectory is very signal‐to‐noise ratio (SNR) efficient and has excellent aliasing properties. A rapid high‐resolution ultra‐short echo time imaging sequence is used to compare the 3D Cones trajectory to 3D projection reconstruction (3DPR) sampling schemes. For equivalent scan times, the 3D Cones trajectory has better SNR performance and fewer aliasing artifacts as compared to the 3DPR trajectory. Magn Reson Med, 2006. © 2006 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.20796

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 13 references

Cited by

See all 335

Metadata

Authors
Gurney, P. T., Hargreaves, B. A., & Nishimura, D. G.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2006-01-31
Volume
55
Issue
3
Pages
575-582
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2048330954
Cited by
335
References
13
FWCI
4.03
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Design and analysis of a practical 3D cones trajectory. https://app.cochat.ai/papers/10.1002/mrm.20796
The paper
Gurney, P. T., Hargreaves, B. A., & Nishimura, D. G. (2006). Design and analysis of a practical 3D cones trajectory. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.20796

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.