The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Reversible intraframe compression of medical images
Abstract
The performance of several reversible, intraframe compression methods is compared by applying them to angiographic and magnetic resonance (MR) images. Reversible data compression involves two consecutive steps: decorrelation and coding. The result of the decorrelation step is presented in terms of entropy. Because Huffman coding generally approximates these entropy measures within a few percent, coding has not been investigated separately. It appears that a hierarchical decorrelation method based on interpolation (HINT) outperforms all other methods considered. The compression ratio is around 3 for angiographic images of 8-9 b/pixel, but is considerably less for MR images whose noise level is substantially higher.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Laplacian pyramid as a compact image code
Burt, P., & Adelson, E. (1983) · IEEE Transactions on Communications · doi:10.1109/tcom.1983.1095851 · Cited by 6,077
Cited by
De Vleeschouwer, C., Delaigle, J.-F., & Macq, B. (2003) · IEEE Transactions on Multimedia · doi:10.1109/tmm.2003.809729 · Cited by 417
Metadata
- Authors
- Roos, P., Viergever, M. A., van Dijke, M. C. A., & Peters, J. H.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 1988-12
- Volume
- 7
- Issue
- 4
- Pages
- 328-336
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2112864115
- Cited by
- 184
- References
- 1
- FWCI
- 7.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reversible intraframe compression of medical images. https://app.cochat.ai/papers/10.1109/42.14516
- The paper
- Roos, P., Viergever, M. A., van Dijke, M. C. A., & Peters, J. H. (1988). Reversible intraframe compression of medical images. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/42.14516
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.