The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Maximum likelihood, least squares, and penalized least squares for PET
Abstract
The EM algorithm is the basic approach used to maximize the log likelihood objective function for the reconstruction problem in positron emission tomography (PET). The EM algorithm is a scaled steepest ascent algorithm that elegantly handles the nonnegativity constraints of the problem. It is shown that the same scaled steepest descent algorithm can be applied to the least squares merit function, and that it can be accelerated using the conjugate gradient approach. The experiments suggest that one can cut the computation by about a factor of 3 by using this technique. The results are applied to various penalized least squares functions which might be used to produce a smoother image.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Maximum Likelihood Reconstruction for Emission Tomography
Shepp, L. A., & Vardi, Y. (1982) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1982.4307558 · Cited by 4,429
A Statistical Model for Positron Emission Tomography
Vardi, Y., Shepp, L. A., & Kaufman, L. (1985) · Journal of the American Statistical Association · doi:10.1080/01621459.1985.10477119 · Cited by 863
Self-citation
Cited by
Space-alternating generalized expectation-maximization algorithm
Fessler, J. A., & Hero, A. O. (1994) · IEEE Transactions on Signal Processing · doi:10.1109/78.324732 · Cited by 1,063
Iterative reconstruction techniques in emission computed tomography
Qi, J., & Leahy, R. M. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/15/r01 · Cited by 415
Fessler, J. A. (1996) · IEEE Transactions on Image Processing · doi:10.1109/83.491322 · Cited by 402
Nuyts, J., Dupont, P., Stroobants, S., Benninck, R., Mortelmans, L., & Suetens, P. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.774167 · Cited by 362
Review of Terahertz Tomography Techniques
Guillet, J. P., Recur, B., Frederique, L., Bousquet, B., Canioni, L., Manek-Hönninger, I., Desbarats, P., & Mounaix, P. (2014) · Journal of Infrared, Millimeter, and Terahertz Waves · doi:10.1007/s10762-014-0057-0 · Cited by 254
Metadata
- Authors
- Kaufman, L.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 1993-06
- Volume
- 12
- Issue
- 2
- Pages
- 200-214
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2081917971
- Cited by
- 180
- References
- 2
- FWCI
- 3.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Maximum likelihood, least squares, and penalized least squares for PET. https://app.cochat.ai/papers/10.1109/42.232249
- The paper
- Kaufman, L. (1993). Maximum likelihood, least squares, and penalized least squares for PET. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/42.232249
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.