The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Automatic ventricular cavity boundary detection from sequential ultrasound images using simulated annealing
Abstract
An automatic algorithm has been developed for high-speed detection of cavity boundaries in sequential 2-D echocardiograms using an optimization algorithm called simulated annealing (SA). The algorithm has three stages. (1) A predetermined window of size nxm is decimated to size n'xm' after low-pass filtering. (2) An iterative radial gradient algorithm is employed to determine the center of gravity (CG) of the cavity. (3) 64 radii which originate from the CG defined in stage 2 are bounded by the high-probability region. Each bounded radius is defined as a link in a 1-D, 64-member cyclic Markov random field. This algorithm is unique in that it compounds spatial and temporal information along with a physical model in its decision rule, whereas most other algorithms base their decisions on spatial data alone. This is the first implementation of a relaxation algorithm for edge detection in echocardiograms. Results attained using this algorithm on real data have been highly encouraging.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Computational Approach to Edge Detection
Canny, J. (1986) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.1986.4767851 · Cited by 30,004
Beitrag zur Theorie des Ferromagnetismus
Ising, E. (1925) · Zeitschrift für Physik · doi:10.1007/bf02980577 · Cited by 3,871
Cited by
Ultrasound image segmentation: a survey
Noble, J. A., & Boukerroui, D. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.877092 · Cited by 1,157
A methodology for evaluation of boundary detection algorithms on medical images
Chalana, V., & Kim, Y. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.640755 · Cited by 542
A multiple active contour model for cardiac boundary detection on echocardiographic sequences
Chalana, V., Linker, D. T., Haynor, D. R., & Kim, Y. (1996) · IEEE Transactions on Medical Imaging · doi:10.1109/42.500138 · Cited by 305
Image-guided control of a robot for medical ultrasound
Abolmaesumi, P., Salcudean, S. E., Zhu, W.-H., Sirouspour, M. R., & DiMaio, S. P. (2002) · IEEE Transactions on Robotics and Automation · doi:10.1109/70.988970 · Cited by 296
Deformable template models: A review
Jain, A. K., Zhong, Y., & Dubuisson-Jolly, M.-P. (1998) · Signal Processing · doi:10.1016/s0165-1684(98)00139-x · Cited by 255
Metadata
- Authors
- Friedland, N., & Adam, D.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 1989
- Volume
- 8
- Issue
- 4
- Pages
- 344-353
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2132447169
- Cited by
- 200
- References
- 2
- FWCI
- 6.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.