The DOI matches its Crossref record.
Wavelet transforms for detecting microcalcifications in mammograms
Abstract
Clusters of fine, granular microcalcifications in mammograms may be an early sign of disease. Individual grains are difficult to detect and segment due to size and shape variability and because the background mammogram texture is typically inhomogeneous. The authors develop a 2-stage method based on wavelet transforms for detecting and segmenting calcifications. The first stage is based on an undecimated wavelet transform, which is simply the conventional filter bank implementation without downsampling, so that the low-low (LL), low-high (LH), high-low (HL), and high-high (HH) sub-bands remain at full size. Detection takes place in HH and the combination LH+HL. Four octaves are computed with 2 inter-octave voices for finer scale resolution. By appropriate selection of the wavelet basis the detection of microcalcifications in the relevant size range can be nearly optimized. In fact, the filters which transform the input image into HH and LH+HL are closely related to prewhitening matched filters for detecting Gaussian objects (idealized microcalcifications) in 2 common forms of Markov (background) noise. The second stage is designed to overcome the limitations of the simplistic Gaussian assumption and provides an accurate segmentation of calcification boundaries. Detected pixel sites in HH and LH+HL are dilated then weighted before computing the inverse wavelet transform. Individual microcalcifications are greatly enhanced in the output image, to the point where straightforward thresholding can be applied to segment them. FROG curves are computed from tests using a freely distributed database of digitized mammograms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Computer-Aided Detection and Diagnosis of Breast Cancer With Mammography: Recent Advances
Tang, J., Rangayyan, R. M., Xu, J., El Naqa, I., & Yang, Y. (2009) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2008.2009441 · Cited by 619
A support vector machine approach for detection of microcalcifications
El-Naqa, I., Yang, Y., Wernick, M. N., Galatsanos, N. P., & Nishikawa, R. M. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.806569 · Cited by 571
Computer-aided detection and classification of microcalcifications in mammograms: a survey
Cheng, H. D., Cai, X., Chen, X., Hu, L., & Lou, X. (2003) · Pattern Recognition · doi:10.1016/s0031-3203(03)00192-4 · Cited by 563
Computer-aided detection/diagnosis of breast cancer in mammography and ultrasound: a review
Jalalian, A., Mashohor, S. B. T., Mahmud, H. R., Saripan, M. I. B., Ramli, A. R. B., & Karasfi, B. (2013) · Clinical Imaging · doi:10.1016/j.clinimag.2012.09.024 · Cited by 337
A review of computer-aided diagnosis of breast cancer: Toward the detection of subtle signs
Rangayyan, R. M., Ayres, F. J., & Leo Desautels, J. E. (2007) · Journal of the Franklin Institute · doi:10.1016/j.jfranklin.2006.09.003 · Cited by 337
Metadata
- Authors
- Strickland, R. N., & Hahn, H. I.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 1996-04
- Volume
- 15
- Issue
- 2
- Pages
- 218-229
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2121915221
- Cited by
- 336
- References
- 0
- FWCI
- 15.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Wavelet transforms for detecting microcalcifications in mammograms. https://app.cochat.ai/papers/10.1109/42.491423
- The paper
- Strickland, R. N., & Hahn, H. I. (1996). Wavelet transforms for detecting microcalcifications in mammograms. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/42.491423
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.