The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Classification algorithms for quantitative tissue characterization of diffuse liver disease from ultrasound images
Abstract
Visual criteria for diagnosing diffused liver diseases from ultrasound images can be assisted by computerized tissue classification. Feature extraction algorithms are proposed in this paper to extract the tissue characterization parameters from liver images. The resulting parameter set is further processed to obtain the minimum number of parameters which represent the most discriminating pattern space for classification. This preprocessing step has been applied to over 120 distinct pathology-investigated cases to obtain the learning data for classification. The extracted features are divided into independent training and test sets, and are used to develop and compare both statistical and neural classifiers. The optimal criteria for these classifiers are set to have minimum classification error, ease of implementation and learning, and the flexibility for future modifications. Various algorithms of classification based on statistical and neural network methods are presented and tested. The authors show that very good diagnostic rates can be obtained using unconventional classifiers trained on actual patient data.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1973) · CERN Document Server (European Organization for Nuclear Research) · Cited by 12,895
Introduction to Statistical Pattern Recognition
(1990) · Elsevier eBooks · doi:10.1016/c2009-0-27872-x · Cited by 11,031
Introduction to statistical pattern recognition (2nd ed.)
Fukunaga, K. (1990) · Academic Press Professional, Inc. eBooks · Cited by 3,797
Pattern Classification and Scene Analysis.
Clarke, M. R. B., Duda, R. O., & Hart, P. E. (1974) · Journal of the Royal Statistical Society. Series A (General) · doi:10.2307/2344977 · Cited by 3,222
Introduction to artificial neural systems
Żurada, J. M. (1992) · Medical Entomology and Zoology · Cited by 2,355
Adaptive pattern recognition and neural networks
(1989) · Choice Reviews Online · doi:10.5860/choice.26-6311 · Cited by 2,313
Introduction to artificial neural systems
Nelson, D., & Wang, J. (1992) · Neurocomputing · doi:10.1016/0925-2312(92)90018-k · Cited by 1,999
Statistics of Speckle in Ultrasound B-Scans
Wagner, R. F., Smith, S. W., Sandrik, J. M., & Lopez, H. (1983) · IEEE Transactions on Sonics and Ultrasonics · doi:10.1109/t-su.1983.31404 · Cited by 1,398
Speckle in ultrasound B-mode scans
Burckhardt, C. B. (1978) · IEEE Transactions on Sonics and Ultrasonics · doi:10.1109/t-su.1978.30978 · Cited by 1,066
Functional-link net computing: theory, system architecture, and functionalities
Pao, Y.-H., & Takefuji, Y. (1992) · Computer · doi:10.1109/2.144401 · Cited by 927
Analysis Of Ultrasound Image Texture Via Generalized Rician Statistics
Insana, M. F., Wagner, R. F., Garra, B. S., Brown, D. G., & Shawker, T. H. (1986) · Optical Engineering · doi:10.1117/12.7973900 · Cited by 225
Raeth, U., Schlaps, D., Limberg, B., ZUNA, I., Lorenz, A., KAICK, G. V., Lorenz, W. J., & Kommerell, B. (1985) · Journal of Clinical Ultrasound · doi:10.1002/jcu.1870130203 · Cited by 189
The accuracy of ultrasound in the detection of fatty infiltration of the liver
Foster, K. J., Dewbury, K. C., Griffith, A. H., & Wright, R. (1980) · The British Journal of Radiology · doi:10.1259/0007-1285-53-629-440 · Cited by 178
Accuracy of ultrasonography in diagnosis of hepatocellular disease
Gosink, B. B., Lemon, S., Scheible, W., et al. (1979) · American Journal of Roentgenology · doi:10.2214/ajr.133.1.19 · Cited by 155
Garra, B. S., Insana, M. F., Shawker, T. H., et al. (1989) · Investigative Radiology · doi:10.1097/00004424-198903000-00004 · Cited by 83
Tissue characterization from ultrasound B-scan data
Nicholas, D., Nassiri, D. K., Garbutt, P., et al. (1986) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(86)90018-9 · Cited by 75
Ultrasound image properties influenced by abdominal wall thickness and composition
Haberkorn, U., Layer, G., Rudat, V., ZUNA, I., Lorenz, A., & KAICK, G. V. (1993) · Journal of Clinical Ultrasound · doi:10.1002/jcu.1870210704 · Cited by 40
Insana, M. F., Garra, B. S., Rosenthal, S. J., & Hall, T. J. (1989) · PubMed · Cited by 15
Cited by
Ultrasound image segmentation: a survey
Noble, J. A., & Boukerroui, D. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.877092 · Cited by 1,157
Texture-based classification of atherosclerotic carotid plaques
Christodoulou, C. I., Pattichis, C. S., Pantziaris, M., & Nicolaides, A. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.815066 · Cited by 316
Cobo, T., Bonet-Carne, E., Martínez-Terrón, M., Perez-Moreno, A., Elías, N., Luque, J., Amat-Roldan, I., & Palacio, M. (2012) · Fetal Diagnosis and Therapy · doi:10.1159/000335349 · Cited by 43
Metadata
- Authors
- Kadah, Y. M., Farag, A. A., Zurada, J. M., Badawi, A. M., & Youssef, A.-B. M.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 1996-08
- Volume
- 15
- Issue
- 4
- Pages
- 466-478
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2162192302
- Cited by
- 265
- References
- 18
- FWCI
- 4.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.