The DOI matches its Crossref record.
Statistics of Speckle in Ultrasound B-Scans
Abstract
the of the magnitude, i.e., intensity, of the field.) It is shown that Rayleigh statistics govern the fist-order behavior of the magnitude; and the autocorrelation of the resulting image speckle is obtained by the methodof Middleton. The corresponding power spectrum follows immediately by Fourier transformation. Theoretical and experimentally determined autocorrelation functions and power spectra derived from B-scans of a scattering phantom containing many scatterers per resolution cell are presented. These functions lead naturally to the definition of the average speckle spot or cell sue, and this inturn is comparable to the resolution cell. Each independent speckle servesas a degreeof freedom that determines the number of samples of tissue available over a target.As the speckle cell size decreases this number increases in a manner predictable from the physical parameters of the cell size. However, it is found that the speckle cellis broadened, the degrees of freedom diminished, when the object structureis correlated. This yields the possibilityof deducing information about the object structure from the second-order statistics of the speckle texture, in addition to that obtainable from the fiistorder statistics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ultrasound image segmentation: a survey
Noble, J. A., & Boukerroui, D. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.877092 · Cited by 1,157
Measurement of Ventricular Torsion by Two-Dimensional Ultrasound Speckle Tracking Imaging
Notomi, Y., Shiota, T., Popović, Z. B., Weaver, J. A., Oryszak, S. J., Greenberg, N. L., White, R. D., Thomas, J. D., Setser, R. M., White, R. D., et al. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.02.082 · Cited by 767
A versatile wavelet domain noise filtration technique for medical imaging
Pizurica, A., Philips, W., Lemahieu, I., & Acheroy, M. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.809588 · Cited by 531
Konofagou, E., & Ophir, J. (1998) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(98)00109-4 · Cited by 444
Speckle tracking methods for ultrasonic elasticity imaging using short-time correlation
Lubinski, M. A., Emelianov, S. Y., & O'Donnell, M. (1999) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.741427 · Cited by 379
Metadata
- Authors
- Wagner, R. F., Smith, S. W., Sandrik, J. M., & Lopez, H.
- Venue
- IEEE Transactions on Sonics and Ultrasonics
- Published
- 1983-05
- Volume
- 30
- Issue
- 3
- Pages
- 156-163
- ISSN
- 0018-9537 (ISSN-L)
- OpenAlex
- W2171857449
- Cited by
- 1,398
- References
- 0
- FWCI
- 14.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Statistics of Speckle in Ultrasound B-Scans. https://app.cochat.ai/papers/10.1109/t-su.1983.31404
- The paper
- Wagner, R. F., Smith, S. W., Sandrik, J. M., & Lopez, H. (1983). Statistics of Speckle in Ultrasound B-Scans. IEEE Transactions on Sonics and Ultrasonics. https://doi.org/10.1109/t-su.1983.31404
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.