Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 208

The DOI matches its Crossref record.

A novel approach to microcalcification detection using fuzzy logic technique

Heng-Da Cheng, Yui Man Lui, Freimanis, R.I. · 1998 · IEEE Transactions on Medical Imaging

Abstract

Breast cancer continues to be a significant public health problem in the United States. Approximately, 182,000 new cases of breast cancer are diagnosed and 46,000 women die of breast cancer each year. Even more disturbing is the fact that one out of eight women in the United States will develop breast cancer at some point during her lifetime. Since the cause of breast cancer remains unknown, primary prevention becomes impossible. Computer-aided mammography is an important and challenging task in automated diagnosis. It has great potential over traditional interpretation of film-screen mammography in terms of efficiency and accuracy. Microcalcifications are the earliest sign of breast carcinomas and their detection is one of the key issues for breast cancer control. In this study, a novel approach to microcalcification detection based on fuzzy logic technique is presented. Microcalcifications are first enhanced based on their brightness and nonuniformity. Then, the irrelevant breast structures are excluded by a curve detector. Finally, microcalcifications are located using an iterative threshold selection method. The shapes of microcalcifications are reconstructed and the isolated pixels are removed by employing the mathematical morphology technique. The essential idea of the proposed approach is to apply a fuzzified image of a mammogram to locate the suspicious regions and to interact the fuzzified image with the original image to preserve fidelity. The major advantage of the proposed method is its ability to detect microcalcifications even in very dense breast mammograms. A series of clinical mammograms are employed to test the proposed algorithm and the performance is evaluated by the free-response receiver operating characteristic curve. The experiments aptly show that the microcalcifications can be accurately detected even in very dense mammograms using the proposed approach.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/42.712133

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 208

Metadata

Authors
Cheng, H.-D., Lui, Y. M., & Freimanis, R. I.
Venue
IEEE Transactions on Medical Imaging
Published
1998-06
Volume
17
Issue
3
Pages
442-450
ISSN
0278-0062 (ISSN-L)
OpenAlex
W2148518080
Cited by
208
References
0
FWCI
5.69
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A novel approach to microcalcification detection using fuzzy logic technique. https://app.cochat.ai/papers/10.1109/42.712133
The paper
Cheng, H.-D., Lui, Y. M., & Freimanis, R. I. (1998). A novel approach to microcalcification detection using fuzzy logic technique. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/42.712133

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.