A comparison of similarity measures for use in 2-D-3-D medical image registration

Penney, G.P., Weese, J., Little, J.A., Desmedt, P., Hill, D.L.G., hawkes, D.J.·1998·IEEE Transactions on Medical Imaging

Abstract

A comparison of six similarity measures for use in intensity-based two-dimensional-three-dimensional (2-D-3-D) image registration is presented. The accuracy of the similarity measures are compared to a "gold-standard" registration which has been accurately calculated using fiducial markers. The similarity measures are used to register a computed tomography (CT) scan of a spine phantom to a fluoroscopy image of the phantom. The registration is carried out within a region-of-interest in the fluoroscopy image which is user defined to contain a single vertebra. Many of the problems involved in this type of registration are caused by features which were not modeled by a phantom image alone. More realistic "gold-standard" data sets were simulated using the phantom image with clinical image features overlaid. Results show that the introduction of soft-tissue structures and interventional instruments into the phantom image can have a large effect on the performance of some similarity measures previously applied to 2-D-3-D image registration. Two measures were able to register accurately and robustly even when soft-tissue structures and interventional instruments were present as differences between the images. These measures were pattern intensity and gradient difference. Their registration accuracy, for all the rigid-body parameters except for the source to film translation, was within a root-mean-square (rms) error of 0.54 mm or degrees to the "gold-standard" values. No failures occ…

Integrity signals

Registry

Crossref · 10.1109/42.730403

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Penney, G. P., Weese, J., Little, J. A., Desmedt, P., Hill, D. L. G., & hawkes, D. J.
Affiliations
  • Guy's Hospital (GB)
  • Philips (Germany) (DE)
  • Philips (Netherlands) (NL)
Venue
IEEE Transactions on Medical Imaging
Published
1998
Volume
17
Issue
4
Pages
586-595
ISSN
0278-0062 (ISSN-L)
OpenAlex
W2134042740
Cited by
782
References
1
Citations by year
2026: 7 · 2025: 15 · 2024: 12 · 2023: 19 · 2022: 15 · 2021: 19 · 2020: 13 · 2019: 10 · 2018: 22 · 2017: 23 · 2016: 31 · 2015: 32 · 2014: 41 · 2013: 45 · 2012: 43
FWCI
16.04
Type
journal article
Language
en
Open access
closed
Locations
  • IEEE Transactions on Medical Imaging (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Medical Image Segmentation Techniques
  • Physical Sciences › Physics and Astronomy › Radiation › Advanced Radiotherapy Techniques
  • Physical Sciences › Engineering › Biomedical Engineering › Medical Imaging and Analysis
Keywords
similarity measures, intensity-based registration, fluoroscopy, computed tomography, spine phantom, soft tissue structures, gradient difference, rigid registration, registration accuracy
MeSH terms
Algorithms, Fluoroscopy, Humans, Spine, Tomography, X-Ray Computed, Phantoms, Imaging

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review