The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Investigation of intraoperative brain deformation using a 1.5-T interventional MR system: preliminary results
Abstract
All image-guided neurosurgical systems that we are aware of assume that the head and its contents behave as a rigid body. It is important to measure intraoperative brain deformation (brain shift) to provide some indication of the application accuracy of image-guided surgical systems, and also to provide data to develop and validate nonrigid registration algorithms to correct for such deformation. We are collecting data from patients undergoing neurosurgery in a high-field (1.5 T) interventional magnetic resonance (MR) scanner. High-contrast and high-resolution gradient-echo MR image volumes are collected immediately prior to surgery, during surgery, and at the end of surgery, with the patient intubated and lying on the operating table in the operative position. In this paper we report initial results from six patients: one freehand biopsy, one stereotactic functional procedure, and four resections. We investigate intraoperative brain deformation by examining threshold boundary overlays and difference images and by measuring ventricular volume. We also present preliminary results obtained using a nonrigid registration algorithm to quantify deformation. We found that some cases had much greater deformation than others, and also that, regardless of the procedure, there was very little deformation of the midline, the tentorium, the hemisphere contralateral to the procedure, and ipsilateral structures except those that are within 1 cm of the lesion or are gravitationally above the surgical site.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nonrigid registration using free-form deformations: application to breast mr images
Rueckert, D., Sonoda, L. I., Hayes, C., Hill, D. L. G., Leach, M. O., & Hawkes, D. J. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.796284 · Cited by 5,265
Self-citation
Cited by
Mutual-information-based registration of medical images: a survey
Pluim, J. P. W., Maintz, J. B. A., & Viergever, M. A. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.815867 · Cited by 2,890
Serial Intraoperative Magnetic Resonance Imaging of Brain Shift
Nabavi, A., Black, P. M., Gering, D. T., Westin, C.-F., Mehta, V., Pergolizzi, R. S., Ferrant, M., Warfield, S. K., Hata, N., Schwartz, R. B., et al. (2001) · Neurosurgery · doi:10.1097/00006123-200104000-00019 · Cited by 461
Rohlfing, T., & Maurer, C. R. (2003) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2003.808506 · Cited by 373
Self-citationA Review of Geometric Transformations for Nonrigid Body Registration
Holden, M. (2008) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2007.904691 · Cited by 369
Schnabel, J. A., Rueckert, D., Quist, M., Blackall, J. M., Castellano-Smith, A. D., Hartkens, T., Penney, G. P., Hall, W. A., Liu, H., Truwit, C. L., et al. (2001) · Lecture Notes in Computer Science · doi:10.1007/3-540-45468-3_69 · Cited by 355
Self-citation
Metadata
- Authors
- Maurer, C. R., Hill, D. L. G., Martin, A. J., Liu, H., McCue, M., Rueckert, D., Lloret, D., Hall, W. A., Maxwell, R. E., Hawkes, D. J., & Truwit, C. L.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 1998
- Volume
- 17
- Issue
- 5
- Pages
- 817-825
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2153860196
- Cited by
- 195
- References
- 1
- FWCI
- 26.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Investigation of intraoperative brain deformation using a 1.5-T interventional MR system: preliminary results. https://app.cochat.ai/papers/10.1109/42.736050
- The paper
- Maurer, C. R., Hill, D. L. G., Martin, A. J., Liu, H., McCue, M., Rueckert, D., Lloret, D., Hall, W. A., Maxwell, R. E., Hawkes, D. J., & Truwit, C. L. (1998). Investigation of intraoperative brain deformation using a 1.5-T interventional MR system: preliminary results. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/42.736050
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.