The DOI matches its Crossref record.
Resampling of data between arbitrary grids using convolution interpolation
Abstract
For certain medical applications resampling of data is required. In magnetic resonance tomography (MRT) or computer tomography (CT), e.g., data may be sampled on nonrectilinear grids in the Fourier domain. For the image reconstruction a convolution-interpolation algorithm, often called gridding, can be applied for resampling of the data onto a rectilinear grid. Resampling of data from a rectilinear onto a nonrectilinear grid are needed, e.g., if projections of a given rectilinear data set are to be obtained. In this paper we introduce the application of the convolution interpolation for resampling of data from one arbitrary grid onto another. The basic algorithm can be split into two steps. First, the data are resampled from the arbitrary input grid onto a rectilinear grid and second, the rectilinear data is resampled onto the arbitrary output grid. Furthermore, we like to introduce a new technique to derive the sampling density function needed for the first step of our algorithm. For fast, sampling-pattern-independent determination of the sampling density function the Voronoi diagram of the sample distribution is calculated. The volume of the Voronoi cell around each sample is used as a measure for the sampling density. It is shown that the introduced resampling technique allows fast resampling of data between arbitrary grids. Furthermore, it is shown that the suggested approach to derive the sampling density function is suitable even for arbitrary sampling patterns. Examples are given in which the proposed technique has been applied for the reconstruction of data acquired along spiral, radial, and arbitrary trajectories and for the fast calculation of projections of a given rectilinearly sampled image.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Advances in sensitivity encoding with arbitrary k‐space trajectories
Pruessmann, K. P., Weiger, M., Börnert, P., & Boesiger, P. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1241 · Cited by 1,211
Rapid gridding reconstruction with a minimal oversampling ratio
Beatty, P. J., Nishimura, D. G., & Pauly, J. M. (2005) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2005.848376 · Cited by 333
A CUDA-based reverse gridding algorithm for MR reconstruction
Yang, J., Feng, C., & Zhao, D. (2013) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2012.06.038 · Cited by 16
Metadata
- Authors
- Rasche, V., Proksa, R., Sinkus, R., Bornert, P., & Eggers, H.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 1999-05
- Volume
- 18
- Issue
- 5
- Pages
- 385-392
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2101493370
- Cited by
- 227
- References
- 0
- FWCI
- 5.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Resampling of data between arbitrary grids using convolution interpolation. https://app.cochat.ai/papers/10.1109/42.774166
- The paper
- Rasche, V., Proksa, R., Sinkus, R., Bornert, P., & Eggers, H. (1999). Resampling of data between arbitrary grids using convolution interpolation. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/42.774166
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.