The DOI matches its Crossref record.
Rapid gridding reconstruction with a minimal oversampling ratio
Abstract
Reconstruction of magnetic resonance images from data not falling on a Cartesian grid is a Fourier inversion problem typically solved using convolution interpolation, also known as gridding. Gridding is simple and robust and has parameters, the grid oversampling ratio and the kernel width, that can be used to trade accuracy for computational memory and time reductions. We have found that significant reductions in computation memory and time can be obtained while maintaining high accuracy by using a minimal oversampling ratio, from 1.125 to 1.375, instead of the typically employed grid oversampling ratio of two. When using a minimal oversampling ratio, appropriate design of the convolution kernel is important for maintaining high accuracy. We derive a simple equation for choosing the optimal Kaiser-Bessel convolution kernel for a given oversampling ratio and kernel width. As well, we evaluate the effect of presampling the kernel, a common technique used to reduce the computation time, and find that using linear interpolation between samples adds negligible error with far less samples than is necessary with nearest-neighbor interpolation. We also develop a new method for choosing the optimal presampled kernel. Using a minimal oversampling ratio and presampled kernel, we are able to perform a three-dimensional (3-D) reconstruction in one-eighth the time and requiring one-third the computer memory versus using an oversampling ratio of two and a Kaiser-Bessel convolution kernel, while maintaining the same level of accuracy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Optimized 3D ultrashort echo time pulmonary MRI
Johnson, K. M., Fain, S. B., Schiebler, M. L., & Nagle, S. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24570 · Cited by 322
Murphy, M., Alley, M., Demmel, J., Keutzer, K., Vasanawala, S., & Lustig, M. (2012) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2012.2188039 · Cited by 313
Technical Note: Deep learning based MRAC using rapid ultrashort echo time imaging
Jang, H., Liu, F., Zhao, G., Bradshaw, T., & McMillan, A. B. (2018) · Medical Physics · doi:10.1002/mp.12964 · Cited by 60
Gai, J., Obeid, N., Holtrop, J. L., Wu, X.-L., Lam, F., Fu, M., Haldar, J. P., Hwu, W.-M. W., Liang, Z.-P., & Sutton, B. P. (2013) · Journal of Parallel and Distributed Computing · doi:10.1016/j.jpdc.2013.01.001 · Cited by 43
Metadata
- Authors
- Beatty, P. J., Nishimura, D. G., & Pauly, J. M.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2005-06
- Volume
- 24
- Issue
- 6
- Pages
- 799-808
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2135730039
- Cited by
- 333
- References
- 0
- FWCI
- 5.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Rapid gridding reconstruction with a minimal oversampling ratio. https://app.cochat.ai/papers/10.1109/tmi.2005.848376
- The paper
- Beatty, P. J., Nishimura, D. G., & Pauly, J. M. (2005). Rapid gridding reconstruction with a minimal oversampling ratio. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2005.848376
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.