The DOI matches its Crossref record.
Homodyne detection in magnetic resonance imaging
Abstract
Magnetic detection of complex images in magnetic resonance imaging (MRI) is immune to the effects of incidental phase variations, although in some applications information is lost or images are degraded. It is suggested that synchronous detection or demodulation can be used in MRI systems in place of magnitude detection to provide complete suppression of undesired quadrature components, to preserve polarity and phase information, and to eliminate the biases and reduction in signal-to-noise ratio (SNR) and contrast in low SNR images. The incidental phase variations in an image are removed through the use of a homodyne demodulation reference, which is derived from the image or the object itself. Synchronous homodyne detection has been applied to the detection of low SNR images, the reconstruction of partial k-space images, the simultaneous detection of water and lipid signals in quadrature, and the preservation of polarity in inversion-recovery images.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 31
- 10.1002/mrm.1910140107 · doi:10.1002/mrm.1910140107
- 10.1002/mrm.1910030104 · doi:10.1002/mrm.1910030104
- 10.1002/j.1538-7305.1948.tb01334.x · DOI · Paper page
- 10.1002/mrm.1910110202 · doi:10.1002/mrm.1910110202
- margosian, 1986, Faster MR imaging: Imaging with half the data, Health Care Instrum, 1, 195
- 10.1148/radiology.161.2.3763926 · DOI · Paper page
- 10.1002/mrm.1910080112 · doi:10.1002/mrm.1910080112
- 10.1109/IEMBS.1989.95888 · doi:10.1109/iembs.1989.95888
- 10.1016/0730-725X(87)90402-4 · doi:10.1016/0730-725x(87)90402-4
- oh, 1987, Faster magnetic resonance imaging by use of 3-quarter matrix data, Proc 7th Annu Meet Soc Magn Res Med, 455
- 10.1016/0730-725X(88)90444-4 · doi:10.1016/0730-725x(88)90444-4
- 10.1097/00004728-198805010-00022 · doi:10.1097/00004728-198805010-00022
- 10.1002/mrm.1910020110 · doi:10.1002/mrm.1910020110
- macovski, 1988, Applications of homodyne detection using separate reference acquisition, Proc 7th Annu Meet Soc Magn Res Med, 983
- 10.1002/mrm.1910040506 · doi:10.1002/mrm.1910040506
- macovski, 1988, Homodyne detection for improved SNR and partiak �-space reconstructions, Proc 7th Annu Meet Soc Magn Res Med, 815
- ziemer, 1976, Principles of Communications
- 10.1109/TMI.1984.4307681 · doi:10.1109/tmi.1984.4307681
- carlson, 1986, Communication Systems
- taub, 1986, Principles of Communication Systems
- middleton, 1960, An Introduction to Statistical Communication Theory
- meyer, 1987, Square spiral fast imaging: Interleaving and off-resonance effects, ?roc 6th Ann Meet Soc Mag Res Med, 230
- 10.1118/1.596304 · doi:10.1118/1.596304
- 10.1118/1.595732 · doi:10.1118/1.595732
- 10.1002/mrm.1910100207 · doi:10.1002/mrm.1910100207
- glasford, 1955, Fundamentals of Television Engineering
- bracewell, 1978, The Fourier Transform arid Its Applications
- paltiel, 1985, Separate water and lipid images obtained by a single scan, Proc 4th Annu Meet Soc Magn Res Med, 172
- patrick, 1985, Water/fat separation and chemical shift artifact correction using a single scan, Proc 4th Annu Meet Soc Magn Res Med, 174
- 10.1148/radiology.153.1.6089263 · DOI · Paper page
- 10.1016/0730-725X(86)90921-5 · doi:10.1016/0730-725x(86)90921-5
Cited by
Schweser, F., Deistung, A., Lehr, B. W., & Reichenbach, J. R. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.10.070 · Cited by 710
Magnetic susceptibility mapping of brain tissue in vivo using MRI phase data
Shmueli, K., de Zwart, J. A., van Gelderen, P., Li, T., Dodd, S. J., & Duyn, J. H. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22135 · Cited by 527
Multicoil Dixon chemical species separation with an iterative least‐squares estimation method
Reeder, S. B., Wen, Z., Yu, H., Pineda, A. R., Gold, G. E., Markl, M., & Pelc, N. J. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10675 · Cited by 508
Slow expansion of multiple sclerosis iron rim lesions: pathology and 7 T magnetic resonance imaging
Dal-Bianco, A., Grabner, G., Kronnerwetter, C., Weber, M., Höftberger, R., Berger, T., Auff, E., Leutmezer, F., Trattnig, S., Lassmann, H., et al. (2017) · Acta Neuropathologica · doi:10.1007/s00401-016-1636-z · Cited by 463
Altered amygdala resting-state functional connectivity in post-traumatic stress disorder
Rabinak, C. A., Angstadt, M., Welsh, R. C., Kenndy, A. E., Lyubkin, M., Martis, B., & Phan, K. L. (2011) · Frontiers in Psychiatry · doi:10.3389/fpsyt.2011.00062 · Cited by 230
Metadata
- Authors
- Noll, D. C., Nishimura, D. G., & Macovski, A.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 1991-06
- Volume
- 10
- Issue
- 2
- Pages
- 154-163
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2106263593
- Cited by
- 514
- References
- 0
- FWCI
- 3.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Homodyne detection in magnetic resonance imaging. https://app.cochat.ai/papers/10.1109/42.79473
- The paper
- Noll, D. C., Nishimura, D. G., & Macovski, A. (1991). Homodyne detection in magnetic resonance imaging. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/42.79473
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.