Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 206

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Modeling the hemodynamic response in fMRI using smooth FIR filters

Open access
Goutte, C., Nielsen, F.A., Hansen, K.H. · 2000 · IEEE Transactions on Medical Imaging

Abstract

Modeling the haemodynamic response in functional magnetic resonance (fMRI) experiments is an important aspect of the analysis of functional neuroimages. This has been done in the past using parametric response function, from a limited family. In this contribution, we adopt a semi-parametric approach based on finite impulse response (FIR) filters. In order to cope with the increase in the number of degrees of freedom, we introduce a Gaussian process prior on the filter parameters. We show how to carry on the analysis by incorporating prior knowledge on the filters, optimizing hyper-parameters using the evidence framework, or sampling using a Markov Chain Monte Carlo (MCMC) approach. We present a comparison of our model with standard haemodynamic response kernels on simulated data, and perform a full analysis of data acquired during an experiment involving visual stimulation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/42.897811

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 206

Metadata

Authors
Goutte, C., Nielsen, F. A., & Hansen, K. H.
Venue
IEEE Transactions on Medical Imaging
Published
2000
Volume
19
Issue
12
Pages
1188-1201
ISSN
0278-0062 (ISSN-L)
OpenAlex
W2158308356
Cited by
206
References
3
FWCI
3.97
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Modeling the hemodynamic response in fMRI using smooth FIR filters. https://app.cochat.ai/papers/10.1109/42.897811
The paper
Goutte, C., Nielsen, F. A., & Hansen, K. H. (2000). Modeling the hemodynamic response in fMRI using smooth FIR filters. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/42.897811

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.