The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Amplitude response and stimulus presentation frequency response of human primary visual cortex using BOLD EPI at 4 T
Abstract
Detailed measurement of the neural response to flicker frequency using functional MRI (fMRI) were made. The fMRl signal peaks at a flicker frequency of 8 Hz in human V1, in agreement with previous positron emission tomography (PET) and fMRl experiments. The modulation amplitude of the hemodynamic response to varying continuous periods of flicker stimulation was measured. The hemodynamic response was not observed to be modulated by neural modulation for periods shorter than 6.7 s. The resemblance between the BOLD response to the stimulus presentation frequency and the base‐line power spectra at the same frequencies suggests that the same underlying mechanism could be responsible for both curves and that the base‐line fMRl power spectrum is probably due to base‐line electrical activity in the brain. The integrals of the resting base‐line power spectrum, the background power spectrum, the respiration component, and the cardiac component were found to be linearly dependent on TE.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The BOLD response in V1 to flickering at full-contrast peaks at 4-8 Hz and settles around 70% of its maximal value even at frequencies above 30 Hz.
“we employed the well-known dependence of BOLD response in V1 to flickering, which at full-contrast peaks at 4–8 Hz and settles around 70% of its maximal value even at frequencies above 30 Hz (Thomas and Menon, 1998)”
From Perception is associated with the brain’s metabolic response to sensory stimulation (2022) · cites this paper as Thomas and Menon, 1998
Citations
Cites
Steady-state evoked potentials
Regan, D. (1977) · Journal of the Optical Society of America · doi:10.1364/josa.67.001475 · Cited by 266
Flagged first, then by citations
Research works printed but not linked: 39
- 10.1073/pnas.87.24.9868 · DOI · Paper page
- 10.1002/(SICI)1099-1492(199706/08)10:4/5<179::AID-NBM463>3.0.CO;2-X · DOI
- 10.1002/mrm.1910380220 · DOI
- Menon R. S., 1995, Diffusion and Perfusion Magnetic Resonance Imaging, 327
- Bandettini P. A., 1995, Diffusion and Perfusion Magnetic Resonance Imaging, 335
- 10.1002/mrm.1910330602 · DOI
- 10.1002/mrm.1910330507 · DOI
- 10.1002/mrm.1910300317 · DOI
- 10.1002/mrm.1910350114 · DOI
- 10.1002/mrm.1910340409 · DOI · Paper page
- P.Jezzard D.LeBihan C.Cuenod L.Pannier A.Prinster R.Turner An investigation of the contribution of physiological noise in human functional MRI studies at 1.5 Tesla and 4 Tesla in“Proc. SMRM 12th Annual Meeting New York 1993 ” p.1392.
- R. M.Weisskoff J.Baker J.Belliveau T. L.Davis K. K.Kwong M. S.Cohen B. R.Rosen Power spectrum analysis of functionally‐weighted MR data: what's in the noise in“Proc. SMRM 12th Annual Meeting New York 1993 ” p.7.
- 10.1523/JNEUROSCI.16-13-04207.1996 · DOI
- 10.1002/mrm.1910330323 · DOI
- Wilson C. L., 1995, Visual receptive fields and response properties of neurons in human temporal lohe and visual pathways, BMin, 106, 473
- 10.1016/0168-5597(88)90010-X · DOI
- 10.1152/jn.1984.51.5.1109 · DOI
- 10.1073/pnas.89.12.5675 · DOI · Paper page
- 10.1126/science.8342027 · DOI
- 10.1002/mrm.1910300204 · DOI
- E. A.Barberi B. K.Rutt R.Menon An all stop birdcage resonator for very high frequency applications in“Proc. ISMRM 4th Annual Meeting New York 1996 ” p.1417.
- Blackman R. B., 1958, The Measurement of Power Spectra
- Hart W. M., 1992, Adler's Physiology of the Eye, 572
- Cremieux J., 1987, Response properties of area 17 neurons in cats reared in stroboscopic illumination, J. Neurophysiol., 57, 1511, 10.1152/jn.1987.57.5.1511 · DOI
- 10.1113/jphysiol.1978.sp012490 · DOI
- Regau D., 1972, Evoked Potentials in Psychology, Sensury Physiology and Clinical Medicine
- Bartley S. H., 1968, Contributions to Sensory Physiology, 81
- 10.1007/BF00362854 · DOI
- Niedermcyer E., 1982, Electroencephalography, 71
- 10.1073/pnas.80.13.4179 · DOI
- 10.1002/mrm.1910370407 · DOI
- 10.1038/jcbfm.1989.84 · DOI
- 10.1038/jcbfm.1992.67 · DOI
- 10.1016/0166-2236(93)90156-G · DOI
- Dumermuth G., 1987, Methods of Analysis of Brain Electrical and Magnetic Signals, 85
- Akaike H., 1981, Recent Advances in EEG and EMG Data Processing, 63
- Cooper R., 1980, EEG Technology
- 10.1002/mrm.1910310505 · DOI
- A. R.Guimaraes J. R.Baker R. M.Weisskoff Cardiac‐gated functional MRI with T1 correction in“Proc. SMR 3rd Annual Meeting Nice 1995 ” p.798. · DOI
Cited by
Sorted by citations
Sex differences in response to red and blue light in human primary visual cortex: a bold fMRI study
Cowan, R. L., Frederick, B. D. B., Rainey, M., Levin, J. M., Maas, L. C., Bang, J., Hennen, J., Lukas, S. E., & Renshaw, P. F. (2000) · Psychiatry Research: Neuroimaging · doi:10.1016/s0925-4927(00)00074-3 · Cited by 65
Perception is associated with the brain’s metabolic response to sensory stimulation
DiNuzzo, M., Mangia, S., Moraschi, M., Mascali, D., Hagberg, G. E., & Giove, F. (2022) · eLife · doi:10.7554/elife.71016 · Cited by 25
“In particular, we employed the well- known dependence of BOLD response in V1 to flickering, which at full- contrast peaks at 4–8 Hz and settles around 70% of its maximal value even at frequencies above 30 Hz (Thomas and Menon, 1998), that is, in the absence of flickering perception.”
Method
Metadata
- Authors
- Thomas, C. G., & Menon, R. S.
- Affiliations
- Western University (CA)
- Corresponding author
- Menon, Ravi S.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1998-08
- Volume
- 40
- Issue
- 2
- Pages
- 203-209
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2049747737
- Cited by
- 77
- References
- 1
- Citations by year
- 2026: 1 · 2025: 1 · 2024: 2 · 2023: 1 · 2022: 2 · 2021: 4 · 2020: 1 · 2019: 1 · 2018: 1 · 2016: 3 · 2015: 1 · 2014: 3
- FWCI
- 4.92
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Magnetic Resonance in Medicine (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced Neuroimaging Techniques and Applications
- Life Sciences › Neuroscience › Cognitive Neuroscience › Visual perception and processing mechanisms
- Keywords
- primary visual cortex, BOLD signal, hemodynamic response, echo time dependence
- MeSH terms
- Adult, Female, Flicker Fusion, Fourier Analysis, Humans, Image Processing, Computer-Assisted, Magnetic Resonance Imaging, Male, Sensory Thresholds, Visual Cortex, Echo-Planar Imaging
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review