CoChat

Artery-vein separation via MRA-An image processing approach

Tianhu Lei, Udupa, J.K., Saha, P.K., Odhner, D. · 2001 · IEEE Transactions on Medical Imaging
Cited by 103

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

This paper presents a near-automatic process for separating vessels from background and other clutter as well as for separating arteries and veins in contrast-enhanced magnetic resonance angiographic (CE-MRA) image data, and an optimal method for three-dimensional visualization of vascular structures. The separation process utilizes fuzzy connected object delineation principles and algorithms. The first step of this separation process is the segmentation of the entire vessel structure from the background and other clutter via absolute fuzzy connectedness. The second step is to separate artery from vein within this entire vessel structure via iterative relative fuzzy connectedness. After seed voxels are specified inside artery and vein in the CE-MRA image, the small regions of the bigger aspects of artery and vein are separated in the initial iterations, and further detailed aspects of artery and vein are included in later iterations. At each iteration, the artery and vein compete among themselves to grab membership of each voxel in the vessel structure based on the relative strength of connectedness of the voxel in the artery and vein. This approach has been implemented in a software package for routine use in a clinical setting and tested on 133 CE-MRA studies of the pelvic region and two studies of the carotid system from six different hospitals. In all studies, unified parameter settings produced correct artery-vein separation. When compared with manual segmentation/separation, our algorithms were able to separate higher order branches, and therefore produced vastly more details in the segmented vascular structure. The total operator and computer time taken per study is on the average about 4.5 min. To date, this technique seems to be the only image processing approach that can be routinely applied for artery and vein separation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/42.938238

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 103

Metadata

Authors
Lei, T., Udupa, J. K., Saha, P. K., & Odhner, D.
Venue
IEEE Transactions on Medical Imaging
Published
2001
Volume
20
Issue
8
Pages
689-703
ISSN
0278-0062 (ISSN-L)
OpenAlex
W2170796484
Cited by
103
References
1
FWCI
11.44
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Artery-vein separation via MRA-An image processing approach. https://app.cochat.ai/papers/10.1109/42.938238
The paper
Lei, T., Udupa, J. K., Saha, P. K., & Odhner, D. (2001). Artery-vein separation via MRA-An image processing approach. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/42.938238

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.