A practical method for position-dependent Compton-scatter correction in single photon emission CT
Abstract
A new method is proposed to subtract the count of scattered photons from that acquired with a photopeak window at each pixel in each planar image of single-photon emission computed tomography (SPECT). The subtraction is carried out using two sets of data: one set is acquired with a main window centered at photopeak energy and the other is acquired with two subwindows on both sides of the main window. The scattered photons included in the main window are estimated from the counts acquired with the subwindows and then they are subtracted from the count acquired with the main windows. Since the subtraction is performed at each pixel in each planar image, the proposed method has the potential to be more precise than conventional methods. For three different activity distributions in cylinder phantoms, simulation tests gave good agreement between the activity distributions reconstructed from unscattered photons and those from the corrected data.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Fourier reconstruction of a head section
Shepp, L. A., & Logan, B. F. (1974) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.1974.6499235 · Cited by 2,179
Photon cross sections from 1 keV to 100 MeV for elements Z=1 to Z=100
Storm, L., & Israel, H. I. (1970) · Atomic Data and Nuclear Data Tables · doi:10.1016/s0092-640x(70)80017-1 · Cited by 1,539
A Method for Attenuation Correction in Radionuclide Computed Tomography
Chang, L.-T. (1978) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.1978.4329385 · Cited by 1,297
Improved SPECT quantification using compensation for scattered photons.
Jaszczak, R. J., Kl, G., Floyd, C. E., Harris, C. C., & Coleman, R. E. (1984) · PubMed · Cited by 555
Inverse Monte Carlo: A Unified Reconstruction Algorithm for SPECT
Floyd, C. E., Jaszczak, R. J., & Coleman, R. E. (1985) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.1985.4336940 · Cited by 196
Scatter Compensation Techniques for SPECT
Jaszczak, R. J., Floyd, C. E., & Coleman, R. E. (1985) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.1985.4336941 · Cited by 133
SPECT dual-energy-window Compton correction: scatter multiplier required for quantification.
Koral, K. F., Swailem, F. M., Buchbinder, S., Clinthorne, N. H., Rogers, W. L., & Tsui, B. M. W. (1990) · PubMed · Cited by 117
Cited by
Ljungberg, M., Celler, A., Konijnenberg, M. W., Eckerman, K. F., Dewaraja, Y. K., & Sjögreen-Gleisner, K. (2016) · Journal of Nuclear Medicine · doi:10.2967/jnumed.115.159012 · Cited by 369
He, B., Wahl, R. L., Du, Y., Sgouros, G., Jacene, H., Flinn, I., & Frey, E. C. (2008) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2007.908131 · Cited by 53
Metadata
- Authors
- Ogawa, K., Harata, Y., Ichihara, T., Kubo, A., & Hashimoto, S.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 1991
- Volume
- 10
- Issue
- 3
- Pages
- 408-412
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2118147340
- Cited by
- 616
- References
- 7
- FWCI
- 8.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A practical method for position-dependent Compton-scatter correction in single photon emission CT. https://app.cochat.ai/papers/10.1109/42.97591
- The paper
- Ogawa, K., Harata, Y., Ichihara, T., Kubo, A., & Hashimoto, S. (1991). A practical method for position-dependent Compton-scatter correction in single photon emission CT. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/42.97591
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.