Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 188

The DOI matches its Crossref record.

Segmentation of ultrasound B-mode images with intensity inhomogeneity correction

Guofang Xiao, Brady, M., Noble, J.A., Yongyue Zhang · 2002 · IEEE Transactions on Medical Imaging

Abstract

Displayed ultrasound (US) B-mode images often exhibit tissue intensity inhomogeneities dominated by nonuniform beam attenuation within the body. This is a major problem for intensity-based, automatic segmentation of video-intensity images because conventional threshold-based or intensity-statistic-based approaches do not work well in the presence of such image distortions. Time gain compensation (TGC) is typically used in standard US machines in an attempt to overcome this. However this compensation method is position-dependent which means that different tissues in the same TGC time-range (or corresponding depth range) will be, incorrectly, compensated by the same amount. Compensation should really be tissue-type dependent but automating this step is difficult. The main contribution of this paper is to develop a method for simultaneous estimation of video-intensity inhomogeities and segmentation of US image tissue regions. The method uses a combination of the maximum a posteriori (MAP) and Markov random field (MRF) methods to estimate the US image distortion field assuming it follows a multiplicative model while at the same time labeling image regions based on the corrected intensity statistics. The MAP step is used to estimate the intensity model parameters while the MRF step provides a novel way of incorporating the distributions of image tissue classes as a spatial smoothness constraint. We explain how this multiplicative model can be related to the ultrasonic physics of image formation to justify our approach. Experiments are presented on synthetic images and a gelatin phantom to evaluate quantitatively the accuracy of the method. We also discuss qualitatively the application of the method to clinical breast and cardiac US images. Limitations of the method and potential clinical applications are outlined in the conclusion.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/42.981233

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 188

Metadata

Authors
Xiao, G., Brady, M., Noble, J. A., & Zhang, Y.
Venue
IEEE Transactions on Medical Imaging
Published
2002
Volume
21
Issue
1
Pages
48-57
ISSN
0278-0062 (ISSN-L)
OpenAlex
W2123139184
Cited by
188
References
0
FWCI
7.11
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Segmentation of ultrasound B-mode images with intensity inhomogeneity correction. https://app.cochat.ai/papers/10.1109/42.981233
The paper
Xiao, G., Brady, M., Noble, J. A., & Zhang, Y. (2002). Segmentation of ultrasound B-mode images with intensity inhomogeneity correction. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/42.981233

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.