The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Initialization, noise, singularities, and scale in height ridge traversal for tubular object centerline extraction
Open accessAbstract
The extraction of the centerlines of tubular objects in two and three-dimensional images is a part of many clinical image analysis tasks. One common approach to tubular object centerline extraction is based on intensity ridge traversal. In this paper, we evaluate the effects of initialization, noise, and singularities on intensity ridge traversal and present multiscale heuristics and optimal-scale measures that minimize these effects. Monte Carlo experiments using simulated and clinical data are used to quantify how these "dynamic-scale" enhancements address clinical needs regarding speed, accuracy, and automation. In particular, we show that dynamic-scale ridge traversal is insensitive to its initial parameter settings, operates with little additional computational overhead, tracks centerlines with subvoxel accuracy, passes branch points, and handles significant image noise. We also illustrate the capabilities of the method for medical applications involving a variety of tubular structures in clinical data from different organs, patients, and imaging modalities.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Press, W. H., Teukolsky, S. A., Vetterling, W. T., & Flannery, B. P. (1994) · Cited by 15,411
Scale-Space Theory in Computer Vision
Lindeberg, T. (1994) · Springer eBooks · doi:10.1007/978-1-4757-6465-9 · Cited by 2,169
(1990) · Extending Explanation-Based Learning by Generalizing the Structure of Explanations · doi:10.1016/b978-0-273-08817-2.50013-3 · Cited by 438
Model-based quantitation of 3-D magnetic resonance angiographic images
Frangi, A. F., Niessen, W. J., Hoogeveen, R. M., van Walsum, T., & Viergever, M. A. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.811279 · Cited by 383
Topology adaptive deformable surfaces for medical image volume segmentation
McInemey, T., & Terzopoulos, D. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.811261 · Cited by 269
Ridges in Image and Data Analysis
Eberly, D. (1996) · Computational Imaging and Vision · doi:10.1007/978-94-015-8765-5 · Cited by 250
Penalized-distance volumetric skeleton algorithm
Bitter, I., Kaufman, A. E., & Sato, M. (2001) · IEEE Transactions on Visualization and Computer Graphics · doi:10.1109/2945.942688 · Cited by 248
Limits to the accuracy of vessel diameter measurement in MR angiography
Hoogeveen, R. M., Bakker, C. J. G., & Viergever, M. A. (1998) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880080608 · Cited by 186
An adaptive segmentation algorithm for time-of-flight MRA data
Wilson, D. L., & Noble, J. A. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.811277 · Cited by 174
Gray-scale skeletonization of small vessels in magnetic resonance angiography
Yim, P. J., Choyke, P. L., & Summers, R. M. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.870662 · Cited by 158
Zoom-Invariant Vision of Figural Shape: The Mathematics of Cores
Pizer, S. M., Eberly, D. H., Fritsch, D., & Morse, B. S. (1998) · Computer Vision and Image Understanding · doi:10.1006/cviu.1997.0563 · Cited by 144
Zoom-Invariant Vision of Figural Shape: The Mathematics of Cores
Pizer, S. M., Eberly, D. H., Morse, B. S., & Fritsch, D. (1996) · Carolina Digital Repository (University of North Carolina at Chapel Hill) · doi:10.17615/gd04-qq42 · Cited by 142
Gerig, G., Koller, T., Székely, G. J., Brechbühler, C., & Kübler, O. (2005) · Springer eBooks · doi:10.1007/bfb0013783 · Cited by 114
Registration and Analysis of Vascular Images
Aylward, S., Jomier, J., Weeks, S., & Bullitt, E. (2003) · International Journal of Computer Vision · doi:10.1023/a:1026126900358 · Cited by 100
Self-citationBullitt, E., Aylward, S., Smith, J. K., Mukherji, S. K., Jiroutek, M. R., & Muller, K. E. (2001) · Medical Image Analysis · doi:10.1016/s1361-8415(01)00037-8 · Cited by 73
Self-citationStimulated Cores and their Applications in Medical Imaging
Fritsch, D., Eberly, D. H., Pizer, S. M., et al. (1994) · Cited by 28
Registration of 3D cerebral vessels with 2D digital angiograms: Clinical evaluation
Bullitt, E., Liu, A., Aylward, S., Coffey, C. S., Stone, J., Mukherji, S. K., Muller, K. E., & Pizer, S. M. (1999) · Academic Radiology · doi:10.1016/s1076-6332(99)80432-2 · Cited by 28
Self-citationDetermining X-ray projections for coil treatments of intracranial aneurysms
Wilson, D. L., Royston, D., Noble, J. A., & Byrne, J. V. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.811309 · Cited by 20
Cited by
A review of 3D vessel lumen segmentation techniques: Models, features and extraction schemes
Lesage, D., Angelini, E. D., Bloch, I., & Funka-Lea, G. (2009) · Medical Image Analysis · doi:10.1016/j.media.2009.07.011 · Cited by 920
A review of vessel extraction techniques and algorithms
Kirbas, C., & Quek, F. (2004) · ACM Computing Surveys · doi:10.1145/1031120.1031121 · Cited by 900
Non-rigid image registration: theory and practice
Crum, W. R., Hartkens, T., & Hill, D. L. G. (2004) · The British Journal of Radiology · doi:10.1259/bjr/25329214 · Cited by 719
Computer analysis of computed tomography scans of the lung: a survey
Sluimer, I., Schilham, A., Prokop, M., & van Ginneken, B. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2005.862753 · Cited by 556
Curve-Skeleton Properties, Applications, and Algorithms
Cornea, N. D., Silver, D., & Min, P. (2007) · IEEE Transactions on Visualization and Computer Graphics · doi:10.1109/tvcg.2007.1002 · Cited by 484
Metadata
- Authors
- Aylward, S. R., & Bullitt, E.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2002
- Volume
- 21
- Issue
- 2
- Pages
- 61-75
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2134756983
- Cited by
- 578
- References
- 18
- FWCI
- 40.06
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.