The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
A technique for extracting physiological parameters and the required input function simultaneously from PET image measurements: theory and simulation study
Open accessAbstract
Positron emission tomography (PET) is an important tool for enabling quantification of human brain function. However, quantitative studies using tracer kinetic modeling require the measurement of the tracer time-activity curve in plasma (PTAC) as the model input function. It is widely believed that the insertion of arterial lines and the subsequent collection and processing of the biomedical signal sampled from the arterial blood are not compatible with the practice of clinical PET, as it is invasive and exposes personnel to the risks associated with the handling of patient blood and radiation dose. Therefore, it is of interest to develop practical noninvasive measurement techniques for tracer kinetic modeling with PET. In this paper, a technique is proposed to extract the input function together with the physiological parameters from the brain dynamic images alone. The identifiability of this method is tested rigorously by using Monte Carlo simulation. The results show that the proposed method is able to quantify all the required parameters by using the information obtained from two or more regions of interest (ROI's) with very different dynamics in the PET dynamic images. There is no significant improvement in parameter estimation for the local cerebral metabolic rate of glucose (LCMRGlc) if the number of ROI's are more than three. The proposed method can provide very reliable estimation of LCMRGlc, which is our primary interest in this study.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Algorithm for Least-Squares Estimation of Nonlinear Parameters
Marquardt, D. W. (1963) · Journal of the Society for Industrial and Applied Mathematics · doi:10.1137/0111030 · Cited by 30,728
Sokoloff, L., Reivich, M., Kennedy, C., Rosiers, M. H. D., Patlak, C. S., Pettigrew, K. D., Sakurada, O., & Shinohara, M. (1977) · Journal of Neurochemistry · doi:10.1111/j.1471-4159.1977.tb10649.x · Cited by 6,000
Cited by
Iterative PET Image Reconstruction Using Convolutional Neural Network Representation
Gong, K., Guan, J., Kim, K., Zhang, X., Yang, J., Seo, Y., El Fakhri, G., Qi, J., & Li, Q. (2019) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2869871 · Cited by 274
Image-Derived Input Function for Brain PET Studies: Many Challenges and Few Opportunities
Zanotti-Fregonara, P., Chen, K., Liow, J.-S., Fujita, M., & Innis, R. B. (2011) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2011.107 · Cited by 263
Direct reconstruction of kinetic parameter images from dynamic PET data
Kamasak, M. E., Bouman, C. A., Morris, E. D., & Sauer, K. (2005) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2005.845317 · Cited by 254
Metadata
- Authors
- Feng, D., Wong, K.-P., Wu, C.-M., & Siu, W.-C.
- Venue
- IEEE Transactions on Information Technology in Biomedicine
- Published
- 1997
- Volume
- 1
- Issue
- 4
- Pages
- 243-254
- ISSN
- 1089-7771 (ISSN-L)
- OpenAlex
- W2131706886
- Cited by
- 189
- References
- 2
- FWCI
- 1.13
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A technique for extracting physiological parameters and the required input function simultaneously from PET image measurements: theory and simulation study. https://app.cochat.ai/papers/10.1109/4233.681168
- The paper
- Feng, D., Wong, K.-P., Wu, C.-M., & Siu, W.-C. (1997). A technique for extracting physiological parameters and the required input function simultaneously from PET image measurements: theory and simulation study. IEEE Transactions on Information Technology in Biomedicine. https://doi.org/10.1109/4233.681168
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.