The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Automatic retinal image registration scheme using global optimization techniques
Open accessAbstract
Retinal image registration is commonly required in order to combine the complementary information in different retinal modalities. In this paper, a new automatic scheme to register retinal images is presented and is currently tested in a clinical environment. The scheme considers the suitability and efficiency of different image transformation models and function optimization techniques, following an initial preprocessing stage. Three different transformation models--affine, bilinear and projective--as well as three optimization techniques--downhill simplex method, simulated annealing and genetic algorithms--are investigated and compared in terms of accuracy and efficiency. The registration of 26 pairs of Fluoroscein Angiography and Indocyanine Green Chorioangiography images with the corresponding Red-Free retinal images, showed the superiority of combining genetic algorithms with the affine and bilinear transformation models. A comparative study of the proposed automatic registration scheme against the manual method, commonly used in the clinical practice, is finally presented showing the advantage of the proposed automatic scheme in terms of accuracy and consistency.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Laplacian pyramid as a compact image code
Burt, P., & Adelson, E. (1983) · IEEE Transactions on Communications · doi:10.1109/tcom.1983.1095851 · Cited by 6,077
Cited by
The dual-bootstrap iterative closest point algorithm with application to retinal image registration
Stewart, C. V., Tsai, C.-L., & Roysam, B. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.819276 · Cited by 346
A Partial Intensity Invariant Feature Descriptor for Multimodal Retinal Image Registration
Chen, J., Tian, J., Lee, N., Zheng, J., Smith, R. T., & Laine, A. F. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2042169 · Cited by 311
Mahfouz, M. R., Hoff, W. A., Komistek, R. D., & Dennis, D. A. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.820027 · Cited by 305
Can, A., Stewart, C. V., Roysam, B., & Tanenbaum, H. L. (2002) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.990136 · Cited by 272
An artificial agent for robust image registration
Liao, R., Miao, S., De Tournemire, P., Grbic, S., Kamen, A., Mansi, T., & Comaniciu, D. (2017) · Proceedings of the AAAI Conference on Artificial Intelligence · doi:10.1609/aaai.v31i1.11230 · Cited by 199
Metadata
- Authors
- Matsopoulos, G. K., Mouravliansky, N. A., Delibasis, K. K., & Nikita, K. S.
- Venue
- IEEE Transactions on Information Technology in Biomedicine
- Published
- 1999-03
- Volume
- 3
- Issue
- 1
- Pages
- 47-60
- ISSN
- 1089-7771 (ISSN-L)
- OpenAlex
- W2167204691
- Cited by
- 189
- References
- 1
- FWCI
- 3.34
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Automatic retinal image registration scheme using global optimization techniques. https://app.cochat.ai/papers/10.1109/4233.748975
- The paper
- Matsopoulos, G. K., Mouravliansky, N. A., Delibasis, K. K., & Nikita, K. S. (1999). Automatic retinal image registration scheme using global optimization techniques. IEEE Transactions on Information Technology in Biomedicine. https://doi.org/10.1109/4233.748975
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.