Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 305

The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.

A robust method for registration of three-dimensional knee implant models to two-dimensional fluoroscopy images

Mahfouz, M.R., Hoff, W.A., Komistek, R.D., Dennis, D.A.·2003·IEEE Transactions on Medical Imaging

Abstract

A method was developed for registering three-dimensional knee implant models to single plane X-ray fluoroscopy images. We use a direct image-to-image similarity measure, taking advantage of the speed of modern computer graphics workstations to quickly render simulated (predicted) images. As a result, the method does not require an accurate segmentation of the implant silhouette in the image (which can be prone to errors). A robust optimization algorithm (simulated annealing) is used that can escape local minima and find the global minimum (true solution). Although we focus on the analysis of total knee arthroplasty (TKA) in this paper, the method can be (and has been) applied to other implanted joints, including, but not limited to, hips, ankles, and temporomandibular joints. Convergence tests on an in vivo image show that the registration method can reliably find poses that are very close to the optimal (i.e., within 0.4 degrees and 0.1 mm), even from starting poses with large initial errors. However, the precision of translation measurement in the Z (out-of-plane) direction is not as good. We also show that the method is robust with respect to image noise and occlusions. However, a small amount of user supervision and intervention is necessary to detect cases when the optimization algorithm falls into a local minimum. Intervention is required less than 5% of the time when the initial starting pose is reasonably close to the correct answer, but up to 50% of the time when the initial starting pose is far away. Finally, extensive evaluations were performed on cadaver images to determine accuracy of relative pose measurement. Comparing against data derived from an optical sensor as a "gold standard," the overall root-mean-square error of the registration method was approximately 1.5 degrees and 0.65 mm (although Z translation error was higher). However, uncertainty in the optical sensor data may account for a large part of the observed error.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tmi.2003.820027

Cites

37 of 37 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 37 references

Cited by

See all 305

Metadata

Authors
Mahfouz, M. R., Hoff, W. A., Komistek, R. D., & Dennis, D. A.
Venue
IEEE Transactions on Medical Imaging
Published
2003-12
Volume
22
Issue
12
Pages
1561-1574
ISSN
0278-0062 (ISSN-L)
OpenAlex
W2099752932
Cited by
305
References
37
FWCI
14.21
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A robust method for registration of three-dimensional knee implant models to two-dimensional fluoroscopy images. https://app.cochat.ai/papers/10.1109/tmi.2003.820027
The paper
Mahfouz, M. R., Hoff, W. A., Komistek, R. D., & Dennis, D. A. (2003). A robust method for registration of three-dimensional knee implant models to two-dimensional fluoroscopy images. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2003.820027

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.