The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Rapid automated tracing and feature extraction from retinal fundus images using direct exploratory algorithms
Abstract
Algorithms are presented for rapid, automatic, robust, adaptive, and accurate tracing of retinal vasculature and analysis of intersections and crossovers. This method improves upon prior work in several ways: 1) automatic adaptation from frame to frame without manual initialization/adjustment, with few tunable parameters; 2) robust operation on image sequences exhibiting natural variability, poor and varying imaging conditions, including over/under-exposure, low contrast, and artifacts such as glare; 3) does not require the vasculature to be connected, so it can handle partial views; and 4) operation is efficient enough for use on unspecialized hardware, and amenable to deadline-driven computing, being able to produce a rapidly and monotonically improving sequence of usable partial results. Increased computation can be traded for superior tracing performance. Its efficiency comes from direct processing on gray-level data without any preprocessing, and from processing only a minimally necessary fraction of pixels in an exploratory manner, avoiding low-level image-wide operations such as thresholding, edge detection, and morphological processing. These properties make the algorithm suited to real-time, on-line (live) processing and is being applied to computer-assisted laser retinal surgery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Detection of blood vessels in retinal images using two-dimensional matched filters
Chaudhuri, S., Chatterjee, S., Katz, N., Nelson, M., & Goldbaum, M. (1989) · IEEE Transactions on Medical Imaging · doi:10.1109/42.34715 · Cited by 1,668
Boundary finding with parametrically deformable models
Staib, L. H., & Duncan, J. S. (1992) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.166621 · Cited by 756
The detection and quantification of retinopathy using digital angiograms
Zhou, L., Rzeszotarski, M. S., Singerman, L. J., & Chokreff, J. M. (1994) · IEEE Transactions on Medical Imaging · doi:10.1109/42.363106 · Cited by 292
Stansfield, S. A. (1986) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.1986.4767772 · Cited by 163
Adaptive boundary detection using 'live-wire' two-dimensional dynamic programming
Mortensen, E. N., Morse, B., Barrett, W. A., & Udupa, J. K. (2003) · Computers in cardiology · doi:10.1109/cic.1992.269378 · Cited by 120
An algorithm for real-time vessel enhancement and detection
Poli, R., & Valli, G. (1997) · Computer Methods and Programs in Biomedicine · doi:10.1016/s0169-2607(96)01773-7 · Cited by 109
Becker, D. E., Can, A., Turner, J. N., Tanenbaum, H. L., & Roysam, B. (1998) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.650362 · Cited by 75
Self-citationReal-time algorithm for retinal tracking
Markow, M. S., Rylander, H. G., & Welch, A. J. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.250583 · Cited by 37
Sun, Y., Lucariello, R. J., & Chiaramida, S. A. (1995) · IEEE Transactions on Medical Imaging · doi:10.1109/42.387705 · Cited by 37
Cited by
Ridge-based vessel segmentation in color images of the retina
Staal, J., Abramoff, M. D., Niemeijer, M., Viergever, M. A., & van Ginneken, B. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.825627 · Cited by 4,202
Design and validation of a tool for neurite tracing and analysis in fluorescence microscopy images
Meijering, E., Jacob, M., Sarria, J. ‐. F., Steiner, P., Hirling, H., & Unser, M. (2004) · Cytometry Part A · doi:10.1002/cyto.a.20022 · Cited by 1,608
Retinal vessel segmentation using the 2-D Gabor wavelet and supervised classification
Soares, J. V. B., Leandro, J. J. G., Cesar, R. M., Jelinek, H. F., & Cree, M. J. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.879967 · Cited by 1,497
Marín, D., Aquino, A., Gegundez-Arias, M. E., & Bravo, J. M. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2064333 · Cited by 929
Retinal Blood Vessel Segmentation Using Line Operators and Support Vector Classification
Ricci, E., & Perfetti, R. (2007) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2007.898551 · Cited by 818
Metadata
- Authors
- Can, A., Shen, H., Turner, Tanenbaum, & Roysam
- Venue
- IEEE Transactions on Information Technology in Biomedicine
- Published
- 1999-06
- Volume
- 3
- Issue
- 2
- Pages
- 125-138
- ISSN
- 1089-7771 (ISSN-L)
- OpenAlex
- W2091585872
- Cited by
- 434
- References
- 9
- FWCI
- 3.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Rapid automated tracing and feature extraction from retinal fundus images using direct exploratory algorithms. https://app.cochat.ai/papers/10.1109/4233.767088
- The paper
- Can, A., Shen, H., Turner, Tanenbaum, & Roysam. (1999). Rapid automated tracing and feature extraction from retinal fundus images using direct exploratory algorithms. IEEE Transactions on Information Technology in Biomedicine. https://doi.org/10.1109/4233.767088
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.