Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 244

The DOI matches its Crossref record.

A virtual-reality-based telerehabilitation system with force feedback

Popescu, V.G., Burdea, G.C., Bouzit, M., Hentz, V.R.·2000·IEEE Transactions on Information Technology in Biomedicine

Abstract

A PC-based orthopedic rehabilitation system was developed for use at home, while allowing remote monitoring from the clinic. The home rehabilitation station has a Pentium II PC with graphics accelerator, a Polhemus tracker, and a multipurpose haptic control interface. This novel interface is used to sample a patient's hand positions and to provide resistive forces using the Rutgers Master II (RMII) glove. A library of virtual rehabilitation routines was developed using WorldToolKit software. At the present time, it consists of three physical therapy exercises (DigiKey, ball, and power putty) and two functional rehabilitation exercises (peg board and ball game). These virtual reality exercises allow automatic and transparent patient data collection into an Oracle database. A remote Pentium II PC is connected with the home-based PC over the Internet and an additional video conferencing connection. The remote computer is running an Oracle server to maintain the patient database, monitor progress, and change the exercise level of difficulty. This allows for patient progress monitoring and repeat evaluations over time. The telerehabilitation system is in clinical trails at Stanford Medical School (CA), with progress being monitored from Rutgers University (NJ). Other haptic interfaces currently under development include devices for elbow and knee rehabilitation connected to the same system.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/4233.826858

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 244

Metadata

Authors
Popescu, V. G., Burdea, G. C., Bouzit, M., & Hentz, V. R.
Venue
IEEE Transactions on Information Technology in Biomedicine
Published
2000-03
Volume
4
Issue
1
Pages
45-51
ISSN
1089-7771 (ISSN-L)
OpenAlex
W2130392023
Cited by
244
References
0
FWCI
25.07
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A virtual-reality-based telerehabilitation system with force feedback. https://app.cochat.ai/papers/10.1109/4233.826858
The paper
Popescu, V. G., Burdea, G. C., Bouzit, M., & Hentz, V. R. (2000). A virtual-reality-based telerehabilitation system with force feedback. IEEE Transactions on Information Technology in Biomedicine. https://doi.org/10.1109/4233.826858

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.