A virtual-reality-based telerehabilitation system with force feedback
Abstract
A PC-based orthopedic rehabilitation system was developed for use at home, while allowing remote monitoring from the clinic. The home rehabilitation station has a Pentium II PC with graphics accelerator, a Polhemus tracker, and a multipurpose haptic control interface. This novel interface is used to sample a patient's hand positions and to provide resistive forces using the Rutgers Master II (RMII) glove. A library of virtual rehabilitation routines was developed using WorldToolKit software. At the present time, it consists of three physical therapy exercises (DigiKey, ball, and power putty) and two functional rehabilitation exercises (peg board and ball game). These virtual reality exercises allow automatic and transparent patient data collection into an Oracle database. A remote Pentium II PC is connected with the home-based PC over the Internet and an additional video conferencing connection. The remote computer is running an Oracle server to maintain the patient database, monitor progress, and change the exercise level of difficulty. This allows for patient progress monitoring and repeat evaluations over time. The telerehabilitation system is in clinical trails at Stanford Medical School (CA), with progress being monitored from Rutgers University (NJ). Other haptic interfaces currently under development include devices for elbow and knee rehabilitation connected to the same system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A survey on robotic devices for upper limb rehabilitation
Maciejasz, P., Eschweiler, J., Gerlach-Hahn, K., Jansen-Troy, A., & Leonhardt, S. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-3 · Cited by 1,210
Virtual Environments for Motor Rehabilitation: Review
Holden, M. K. (2005) · CyberPsychology & Behavior · doi:10.1089/cpb.2005.8.187 · Cited by 1,154
Virtual reality-enhanced stroke rehabilitation
Jack, D., Boian, R., Merians, A. S., Tremaine, M., Burdea, G. C., Adamovich, S. V., Recce, M., & Poizner, H. (2001) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/7333.948460 · Cited by 733
Self-citationA Survey of Glove-Based Systems and Their Applications
Dipietro, L., Sabatini, A. M., & Dario, P. (2008) · IEEE Transactions on Systems, Man, and Cybernetics, Part C (Applications and Reviews) · doi:10.1109/tsmcc.2008.923862 · Cited by 691
The Rutgers Master II-new design force-feedback glove
Bouzit, M., Burdea, G., Popescu, G., & Boian, R. (2002) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2002.1011262 · Cited by 570
Self-citation
Metadata
- Authors
- Popescu, V. G., Burdea, G. C., Bouzit, M., & Hentz, V. R.
- Venue
- IEEE Transactions on Information Technology in Biomedicine
- Published
- 2000-03
- Volume
- 4
- Issue
- 1
- Pages
- 45-51
- ISSN
- 1089-7771 (ISSN-L)
- OpenAlex
- W2130392023
- Cited by
- 244
- References
- 0
- FWCI
- 25.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A virtual-reality-based telerehabilitation system with force feedback. https://app.cochat.ai/papers/10.1109/4233.826858
- The paper
- Popescu, V. G., Burdea, G. C., Bouzit, M., & Hentz, V. R. (2000). A virtual-reality-based telerehabilitation system with force feedback. IEEE Transactions on Information Technology in Biomedicine. https://doi.org/10.1109/4233.826858
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.