CoChat

Solving the inverse problem in magnetocardiography

Nenonen, J.T. · 1994 · IEEE Engineering in Medicine and Biology Magazine
Cited by 59

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

Biomagnetic methods have proven to be valuable as research tools in obtaining functional information that is difficult to gain by conventional clinical imaging methods. Still, the magnetocardiographic localization method has to compete with corresponding bioelectric measurements and other noninvasive methods, such as two-dimensional echocardiography, magnetic resonance imaging, and gated X-ray and radionuclide imaging. All of these methods have their limitations, and the later ones may, in certain cases, afford some risk to the patient. So far, the must successful application of biomagnetic methods has been the localization of bioelectric sources in the body. Promising results have been reported, with accuracies comparable to the localization results obtained by invasive clinical methods. Considering the possible clinical use of magnetocardiographs, the localization of arrhythmogenic regions as well as selection of patients with high risk of arrhythmias and sudden cardiac death are important. Theoretically, the advantage of biomagnetic measurements over corresponding bioelectric surface potential studies is still controversial. However, in practice, the spatial resolution capability of biomagnetic methods seems to be better. In various studies, the combination of both magnetic and electric data can bring improvements in the inverse solution.>

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/51.310989

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 59

Metadata

Authors
Nenonen, J. T.
Venue
IEEE Engineering in Medicine and Biology Magazine
Published
1994-08
Volume
13
Issue
4
Pages
487-496
ISSN
0739-5175 (ISSN-L)
OpenAlex
W2092219716
Cited by
59
References
5
FWCI
2.40
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.