Abstract

Solving the inverse problem of electrocardiography (ECG) and magnetocardiography (MCG) is often referred to as cardiac source imaging. Spatial properties of ECG and MCG as imaging systems are, however, not well known. In this modelling study, we investigate the sensitivity and point-spread function (PSF) of ECG, MCG, and combined ECG+MCG as a function of source position and orientation, globally around the ventricles: signal topographies are modelled using a realistically-shaped volume conductor model, and the inverse problem is solved using a distributed source model and linear source estimation with minimal use of prior information. The results show that the sensitivity depends not only on the modality but also on the location and orientation of the source and that the sensitivity distribution is clearly reflected in the PSF. MCG can better characterize tangential anterior sources (with respect to the heart surface), while ECG excels with normally-oriented and posterior sources. Compared to either modality used alone, the sensitivity of combined ECG+MCG is less dependent on source orientation per source location, leading to better source estimates. Thus, for maximal sensitivity and optimal source estimation, the electric and magnetic measurements should be combined.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/0031-9155/59/23/7141

Cites

57 of 57 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 57 references

Research works printed but not linked: 3

  1. Dössel O, 2000, Int. J. Bioelectromagn., 2
  2. 10.5405/jmbe.1026 · doi:10.5405/jmbe.1026
  3. Oostendorp T, 2001, Proc. 12th Int. Conf. on Biomagnetism, 813

Cited by

See all 45

Metadata

Authors
Mäntynen, V., Konttila, T., & Stenroos, M.
Affiliations
  • Helsinki University Hospital (FI)
  • Aalto University (FI)
Corresponding author
Mäntynen, Ville
Venue
Physics in Medicine and Biology
Published
2014-11-03
Volume
59
Issue
23
Pages
7141-7158
ISSN
  • 0031-9155 (ISSN-L)
  • 1361-6560
OpenAlex
W2070183748
Cited by
45
References
58
Citations by year
2026: 10 · 2025: 9 · 2024: 9 · 2023: 1 · 2022: 2 · 2021: 3 · 2020: 2 · 2019: 2 · 2017: 3 · 2016: 2 · 2015: 2
FWCI
1.60
Type
journal article
Language
en
Open access
Licence
Locations
  • Physics in Medicine and Biology (publishedVersion, cc-by)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrical and Bioimpedance Tomography
  • Physical Sciences › Mathematics › Mathematical Physics › Numerical methods in inverse problems
Keywords
electrocardiogram, magnetocardiography, inverse problems, sensitivity distribution, point spread function, thorax model, volume conductor model, distributed source model, source orientation
MeSH terms
Electrocardiography, Heart, Humans, Models, Cardiovascular, Sensitivity and Specificity, Thorax, Magnetocardiography

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Investigations of sensitivity and resolution of ECG and MCG in a realistically shaped thorax model. https://app.cochat.ai/papers/10.1088/0031-9155/59/23/7141
The paper
Mäntynen, V., Konttila, T., & Stenroos, M. (2014). Investigations of sensitivity and resolution of ECG and MCG in a realistically shaped thorax model. Physics in Medicine and Biology. https://doi.org/10.1088/0031-9155/59/23/7141

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.