Cited by 129Electrochemical sensors and biosensorsDiabetes Management and ResearchBiosensors and Analytical Detection

The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.

Noninvasively measuring blood glucose using saliva

Yamaguchi, M., Mitsumori, M., Kano, Y.·1998·IEEE Engineering in Medicine and Biology Magazine

Abstract

Self-measurement of blood glucose level is a very important aspect in monitoring the health quality of diabetic patients who require insulin therapy. Typically, a blood sample for analysis is obtained via a finger stick or other such invasive procedure. Often, this blood collecting causes physical and mental stress to the patient. For this reason, it is desirable to establish a noninvasive bloodless procedure to monitor the blood glucose level (BGL). Here, the authors discuss the correlation between BGL and saliva glucose level and then present an approach that uses an enzyme-sensor system to noninvasively measure blood glucose using saliva.

Overview

Integrity signals

Registry

Crossref · 10.1109/51.677170

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Flagged first, then by citations

Show all 13 references

Research works printed but not linked: 3

  1. yamaguchi, 1997, Pesonal correlation of blood and saliva glucose, J Japan Diabetes Society, 40, 335
  2. kodama, 1991, Evaluation of ANTSENSE, a compact glucose analyzer with use of enzyme electrode method, Medical pharmacology, 26, 97
  3. fekete, 1986, Glucose in the saliva of diabetes, Cas Lek Cesk, 125, 330

Cited by

Sorted by citations

Items 101–129 of 129

Metadata

Authors
Yamaguchi, M., Mitsumori, M., & Kano, Y.
Affiliations
Tokyo University of Agriculture and Technology (JP)
Venue
IEEE Engineering in Medicine and Biology Magazine
Published
1998
Volume
17
Issue
3
Pages
59-63
ISSN
0739-5175 (ISSN-L)
OpenAlex
W2052875889
Cited by
129
References
13
Citations by year
2026: 3 · 2025: 7 · 2024: 12 · 2023: 6 · 2022: 4 · 2021: 9 · 2020: 4 · 2019: 7 · 2018: 3 · 2017: 10 · 2016: 14 · 2015: 13 · 2014: 7 · 2013: 1 · 2012: 5
FWCI
1.46
Type
journal article
Language
en
Open access
closed
Locations
  • IEEE Engineering in Medicine and Biology Magazine (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • Sumitomo Foundation
  • Saneyoshi Scholarship Foundation
Topics
  • Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
  • Physical Sciences › Engineering › Biomedical Engineering › Biosensors and Analytical Detection
Keywords
non-invasive blood glucose measurement, saliva glucose, blood glucose monitoring, diabetes mellitus, insulin therapy, enzyme biosensor, self-monitoring
MeSH terms
Adult, Blood Glucose, Glucose, Humans, Reference Values, Saliva, Time Factors, Reproducibility of Results

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review