The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
The impact of the MIT-BIH Arrhythmia Database
Abstract
The MIT-BIH Arrhythmia Database was the first generally available set of standard test material for evaluation of arrhythmia detectors, and it has been used for that purpose as well as for basic research into cardiac dynamics at about 500 sites worldwide since 1980. It has lived a far longer life than any of its creators ever expected. Together with the American Heart Association Database, it played an interesting role in stimulating manufacturers of arrhythmia analyzers to compete on the basis of objectively measurable performance, and much of the current appreciation of the value of common databases, both for basic research and for medical device development and evaluation, can be attributed to this experience. In this article, we briefly review the history of the database, describe its contents, discuss what we have learned about database design and construction, and take a look at some of the later projects that have been stimulated by both the successes and the limitations of the MIT-BIH Arrhythmia Database.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Holter, N. J. (1961) · Science · doi:10.1126/science.134.3486.1214 · Cited by 568
The MIT-BIH Arrhythmia Database on CD-ROM and software for use with it
Moody, G. B., & Mark, R. G. (2002) · [1990] Proceedings Computers in Cardiology · doi:10.1109/cic.1990.144205 · Cited by 404
Self-citationPhysioNet: a Web-based resource for the study of physiologic signals
Moody, G. B., Mark, R. G., & Goldberger, A. L. (2001) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.932728 · Cited by 386
Self-citationStandards and applicable databases for long-term ECG monitoring.
Moody, G. B., Feldman, C. L., & Bailey, J. J. (1993) · PubMed · Cited by 12
Self-citationEvaluation of Automated Arrhythmia Monitors Using an Annotated ECG DATABASE
Mark, R. G., & Moody, G. B. (1984) · Developments in cardiovascular medicine · doi:10.1007/978-94-009-6012-1_26 · Cited by 9
Self-citation
Research works printed but not linked: 9
- Schluter, 1981, Performance measures for arrhythmia detectors
- Mark, An annotated ECG database for evaluating arrhythmia detectors, 205
- Moody, 1984, How can we predict real-world performance of an arrhythmia detector?, 71
- 1987, Testing and Reporting Performance Results of Ventricular Arrhythmia Detection Algorithms [AAMI ECAR]. Assoc. for the Advancement of Medical Instrumentation
- 1998, American National Standard for Ambulatory Electrocardiographs. AAMI/ANSI Standard EC38:1998
- 1998, American National Standard for Testing and Reporting Performance Results of Cardiac Rhythm and ST Segment Measurement Algorithms. AAMI/ANSI Standard EC57:1998
- Hermes, 1981, Development, distribution, and use of the American Heart Association database for ventricular arrhythmia detector evaluation, 263
- 10.1109/CIC.1990.144191 · doi:10.1109/cic.1990.144191
- 10.1109/CIC.1998.731793 · doi:10.1109/cic.1998.731793
Cited by
Real-Time Patient-Specific ECG Classification by 1-D Convolutional Neural Networks
Kiranyaz, S., Ince, T., & Gabbouj, M. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2468589 · Cited by 1,912
PTB-XL, a large publicly available electrocardiography dataset
Wagner, P., Strodthoff, N., Bousseljot, R.-D., Kreiseler, D., Lunze, F. I., Samek, W., & Schaeffter, T. (2020) · Scientific Data · doi:10.1038/s41597-020-0495-6 · Cited by 1,315
Rahmani, A. M., Gia, T. N., Negash, B., Anzanpour, A., Azimi, I., Jiang, M., & Liljeberg, P. (2018) · Future Generation Computer Systems · doi:10.1016/j.future.2017.02.014 · Cited by 1,198
Saeed, M., Villarroel, M., Reisner, A. T., Clifford, G., Lehman, L.-W., Moody, G., Heldt, T., Kyaw, T. H., Moody, B., & Mark, R. G. (2011) · Critical Care Medicine · doi:10.1097/ccm.0b013e31820a92c6 · Cited by 1,162
“MIMIC-II may serve a role analogous to the public access arrhythmia databases that played an indispensable role in the development, refinement, and—ultimately—widespread acceptance of automated algorithms for electrocardiogram analysis [21].”
Self-citationTranAD: deep transformer networks for anomaly detection in multivariate time series data
Tuli, S., Casale, G., & Jennings, N. R. (2022) · Proceedings of the VLDB Endowment · doi:10.14778/3514061.3514067 · Cited by 1,063
Metadata
- Authors
- Moody, G. B., & Mark, R. G.
- Venue
- IEEE Engineering in Medicine and Biology Magazine
- Published
- 2001
- Volume
- 20
- Issue
- 3
- Pages
- 45-50
- ISSN
- 0739-5175 (ISSN-L)
- OpenAlex
- W2095409369
- Cited by
- 4,812
- References
- 5
- FWCI
- 3.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.