The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Ultrasonic beam focusing through tissue inhomogeneities with a time reversal mirror: application to transskull therapy
Abstract
Time reversal of ultrasonic fields allows a very efficient approach to focus pulsed ultrasonic waves through lossless inhomogeneous media. Time reversal mirrors (TRMs) are made of large transducer arrays, allowing the incident field to be sampled, time reversed, and reemitted. Time reversal method corrects for phase, amplitude, and even shape aberration and thus, is more efficient than time shift compensation techniques. However, this technique needs the knowledge of the Green's function of a dominant scatterer available in the medium. Aberration correction for ultrasonic hyperthermia could be achieved by combining TRM with an artificial acoustic source or sensor implanted inside the treatment volume. In this paper, time reversal method has been experimentally applied to the focusing through the skull bone. It is shown that the skull induces severe attenuation of ultrasound and reduces the efficiency of the time reversal approach. Then, an amplitude correction method is proposed to focus through an attenuating layer located close to the array. This method consists in inversing the amplitude modulation and then time reversing these signals. Finally, this method is combined with numerical backpropagation to compensate for an attenuating layer located some distance away from the transducer array.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Time reversal of ultrasonic fields. I. Basic principles
Fink, M. (1992) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/58.156174 · Cited by 1,525
Self-citationFlax, S. W., & O’Donnell, M. (1988) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/58.9333 · Cited by 483
(1993) · NDT & E International · doi:10.1016/0963-8695(93)90667-j · Cited by 395
Phase aberration correction in medical ultrasound using speckle brightness as a quality factor
Nock, L., Trahey, G. E., & Smith, S. W. (1989) · The Journal of the Acoustical Society of America · doi:10.1121/1.397889 · Cited by 331
Cited by
Fink, M. (1997) · Physics Today · doi:10.1063/1.881692 · Cited by 804
Self-citationHynynen, K., McDannold, N., Sheikov, N. A., Jolesz, F. A., & Vykhodtseva, N. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2004.06.046 · Cited by 679
High intensity focused ultrasound in clinical tumor ablation
Zhou, Y.-F. (2011) · World Journal of Clinical Oncology · doi:10.5306/wjco.v2.i1.8 · Cited by 625
Aubry, J.-F., Tanter, M., Pernot, M., Thomas, J.-L., & Fink, M. (2003) · The Journal of the Acoustical Society of America · doi:10.1121/1.1529663 · Cited by 581
Self-citationMcDannold, N., Clement, G. T., Black, P., Jolesz, F., & Hynynen, K. (2010) · Neurosurgery · doi:10.1227/01.neu.0000360379.95800.2f · Cited by 555
Metadata
- Authors
- Thomas, J.-L., & Fink, M. A.
- Venue
- IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control
- Published
- 1996-11
- Volume
- 43
- Issue
- 6
- Pages
- 1122-1129
- ISSN
- 0885-3010 (ISSN-L)
- OpenAlex
- W2128508537
- Cited by
- 312
- References
- 4
- FWCI
- 7.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.