Progress at NIST toward absolute frequency standards using stored ions
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Experiments directed toward the realization of frequency standards of high accuracy using stored ions are briefly summarized. In one experiment, an RF oscillator is locked to a nuclear spin-flip hyperfine transition (frequency approximately 3.03x10(8) Hz) in (9 )Be(+) ions that are stored in a Penning trap and sympathetically laser-cooled. Stability is better than 3x10(-12)tau(-(1/2)) and uncertainty in Doppler shifts is estimated to be less than 5x10(-15). In a second experiment, a stable laser is used to probe an electric quadrupole transition (frequency approximately 1.07x10(15) Hz) in a single laser-cooled (199)Hg(+) ion stored in a Paul trap. The measured Q value of this transition is approximately 10(13). Future possible experiments are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Test of the linearity of quantum mechanics by rf spectroscopy of theBe+9ground state
Bollinger, J. J., Heinzen, D. J., Itano, W. M., Gilbert, S. L., & Wineland, D. J. (1989) · Physical Review Letters · doi:10.1103/physrevlett.63.1031 · Cited by 151
Self-citation
Cited by
Improvement of Frequency Standards with Quantum Entanglement
Huelga, S. F., Macchiavello, C., Pellizzari, T., Ekert, A. K., Plenio, M. B., & Cirac, J. I. (1997) · Physical Review Letters · doi:10.1103/physrevlett.79.3865 · Cited by 999
Minimization of ion micromotion in a Paul trap
Berkeland, D. J., Miller, J. D., Bergquist, J. C., Itano, W. M., & Wineland, D. J. (1998) · Journal of Applied Physics · doi:10.1063/1.367318 · Cited by 720
Self-citationIonic crystals in a linear Paul trap
Raizen, M. G., Gilligan, J. M., Bergquist, J. C., Itano, W. M., & Wineland, D. J. (1992) · Physical Review A · doi:10.1103/physreva.45.6493 · Cited by 329
Self-citationA 303-MHz frequency standard based on trapped Be/sup +/ ions
Bollinger, J. J., Heizen, D. J., Itano, W. M., Gilbert, S. L., & Wineland, D. J. (1991) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.1990.1032897 · Cited by 169
Self-citation
Metadata
- Authors
- Wineland, D. J., Bergquist, J. C., Bollinger, J. J., Itano, W. M., Heinzen, D. J., Gilbert, S. L., Manney, C. H., & Raizen, M. G.
- Venue
- IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control
- Published
- 1990-11
- Volume
- 37
- Issue
- 6
- Pages
- 515-523
- ISSN
- 0885-3010 (ISSN-L)
- OpenAlex
- W2149921526
- Cited by
- 67
- References
- 1
- FWCI
- 5.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Progress at NIST toward absolute frequency standards using stored ions. https://app.cochat.ai/papers/10.1109/58.63107
- The paper
- Wineland, D. J., Bergquist, J. C., Bollinger, J. J., Itano, W. M., Heinzen, D. J., Gilbert, S. L., Manney, C. H., & Raizen, M. G. (1990). Progress at NIST toward absolute frequency standards using stored ions. IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control. https://doi.org/10.1109/58.63107
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.