The DOI matches its Crossref record.
An adaptive strain estimator for elastography
Abstract
Elastography is based on the estimation of strain due to applied tissue compression. In conventional elastography, strain is computed from the gradient of the displacement estimates between gated pre- and postcompression echo signals. Gradient-based estimation methods are known to be susceptible to noise. In elastography, in addition to the electronic noise, a principal source of estimation error is the decorrelation of the echo signal as a result of tissue compression (decorrelation noise). Temporal stretching of postcompression signals previously was shown to reduce the decorrelation noise. In this paper, we introduce a novel estimator that uses the stretch factor itself as an estimator of the strain. It uses an iterative algorithm that adaptively maximises the correlation between the pre- and postcompression echo signals by appropriately stretching the latter. We investigate the performance of this adaptive strain estimator using simulated and experimental data. The estimator has exhibited a vastly superior performance compared with the conventional gradient-based estimator.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Elastography: Ultrasonic estimation and imaging of the elastic properties of tissues
Ophir, J., Alam, S. K., Garra, B., Kallel, F., Konofagou, E., Krouskop, T., & Varghese, T. (1999) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1243/0954411991534933 · Cited by 784
Self-citationMedical ultrasound: imaging of soft tissue strain and elasticity
Wells, P. N. T., & Liang, H.-D. (2011) · Journal of The Royal Society Interface · doi:10.1098/rsif.2011.0054 · Cited by 538
Konofagou, E., & Ophir, J. (1998) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(98)00109-4 · Cited by 444
Self-citationShear elasticity probe for soft tissues with 1-D transient elastography
Sandrin, L., Tanter, M., Gennisson, J.-L., Catheline, S., & Fink, M. (2002) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.996561 · Cited by 427
Elastography: Imaging the elastic properties of soft tissues with ultrasound
Ophir, J., Alam, S. K., Garra, B. S., Kallel, F., Konofagou, E. E., Krouskop, T., Merritt, C. R. B., Righetti, R., Souchon, R., Srinivasan, S., et al. (2002) · Journal of Medical Ultrasonics · doi:10.1007/bf02480847 · Cited by 366
Self-citation
Metadata
- Authors
- Alam, S. K., Ophir, J., & Konofagou, E. E.
- Venue
- IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control
- Published
- 1998-03
- Volume
- 45
- Issue
- 2
- Pages
- 461-472
- ISSN
- 0885-3010 (ISSN-L)
- OpenAlex
- W2101045015
- Cited by
- 198
- References
- 0
- FWCI
- 6.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An adaptive strain estimator for elastography. https://app.cochat.ai/papers/10.1109/58.660156
- The paper
- Alam, S. K., Ophir, J., & Konofagou, E. E. (1998). An adaptive strain estimator for elastography. IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control. https://doi.org/10.1109/58.660156
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.