The DOI matches its Crossref record.
Shear elasticity probe for soft tissues with 1-D transient elastography
Abstract
Important tissue parameters such as elasticity can be deduced from the study of the propagation of low frequency shear waves. A new method for measuring the shear velocity in soft tissues is presented in this paper. Unlike conventional transient elastography, in which the ultrasonic transducer and the low frequency vibrator are two separated parts, the new method relies on a probe that associates the vibrator and the transducer, which is built on the axis of the vibrator. This setup is easy to use. The low frequency shear wave is driven by the transducer itself that acts as a piston while it is used in pulse echo mode to acquire ultrasonic lines. The results obtained with the new method are in good agreement with those obtained with the conventional one.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Transient elastography: a new noninvasive method for assessment of hepatic fibrosis
Sandrin, L., Fourquet, B., Hasquenoph, J.-M., Yon, S., Fournier, C., Mal, F., Christidis, C., Ziol, M., Poulet, B., Kazemi, F., et al. (2003) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2003.07.001 · Cited by 2,738
Self-citationXiao, G., Zhu, S., Xiao, X., Yan, L., Yang, J., & Wu, G. (2017) · Hepatology · doi:10.1002/hep.29302 · Cited by 895
Fraquelli, M., Rigamonti, C., Casazza, G., Conte, D., Donato, M. F., Ronchi, G., & Colombo, M. (2007) · Gut · doi:10.1136/gut.2006.111302 · Cited by 854
Ganne-Carrié, N., Ziol, M., de Ledinghen, V., Douvin, C., Marcellin, P., Castera, L., Dhumeaux, D., Trinchet, J.-C., & Beaugrand, M. (2006) · Hepatology · doi:10.1002/hep.21420 · Cited by 508
Palmeri, M. L., Wang, M. H., Rouze, N. C., Abdelmalek, M. F., Guy, C. D., Moser, B., Diehl, A. M., & Nightingale, K. R. (2011) · Journal of Hepatology · doi:10.1016/j.jhep.2010.12.019 · Cited by 344
Metadata
- Authors
- Sandrin, L., Tanter, M., Gennisson, J.-L., Catheline, S., & Fink, M.
- Venue
- IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control
- Published
- 2002-04
- Volume
- 49
- Issue
- 4
- Pages
- 436-446
- ISSN
- 0885-3010 (ISSN-L)
- OpenAlex
- W2096995350
- Cited by
- 427
- References
- 0
- FWCI
- 8.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Shear elasticity probe for soft tissues with 1-D transient elastography. https://app.cochat.ai/papers/10.1109/58.996561
- The paper
- Sandrin, L., Tanter, M., Gennisson, J.-L., Catheline, S., & Fink, M. (2002). Shear elasticity probe for soft tissues with 1-D transient elastography. IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control. https://doi.org/10.1109/58.996561
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.