The DOI matches its Crossref record.
High-speed ultrasound volumetric imaging system. II. Parallel processing and image display
Abstract
For pt.I see ibid., vol.38, no.2, p.100-8 (1991). The authors describe the design, application, and evaluation of parallel processing to the high-speed volumetric ultrasound imaging system. The scanner produces images analogous to an optical camera or the human eye and supplies more information than conventional sonograms. Potential medical applications include improved anatomic visualization, tumor localization, and better assessment of cardiac function. The system uses pulse-echo phased array principles to steer a 2-D array transducer of 289 elements in a pyramidal scan format. Parallel processing in the receive mode produces 4992 scan lines at a rate of approximately 8 frames/s. Echo data for the scanned volume is presented online as projection images with depth perspective, stereoscopic pairs, or multiple tomographic images. The authors also describe the techniques developed for the online display of volumetric images on a conventional CRT oscilloscope and show preliminary volumetric images for each display mode.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Three-dimensional ultrasound imaging
Fenster, A., Downey, D. B., & Cardinal, H. N. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/5/201 · Cited by 812
Metadata
- Authors
- von Ramm, O. T., Smith, S. W., & Pavy, H. G.
- Venue
- IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control
- Published
- 1991-03
- Volume
- 38
- Issue
- 2
- Pages
- 109-115
- ISSN
- 0885-3010 (ISSN-L)
- OpenAlex
- W2152672523
- Cited by
- 396
- References
- 0
- FWCI
- 6.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High-speed ultrasound volumetric imaging system. II. Parallel processing and image display. https://app.cochat.ai/papers/10.1109/58.68467
- The paper
- von Ramm, O. T., Smith, S. W., & Pavy, H. G. (1991). High-speed ultrasound volumetric imaging system. II. Parallel processing and image display. IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control. https://doi.org/10.1109/58.68467
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.