Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 167

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Diffraction field of a low frequency vibrator in soft tissues using transient elastography

Catheline, S., Thomas, J.-L., Wu, F., Fink, M.A. · 1999 · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control

Abstract

For the last 10 years, interest has grown in low frequency shear waves that propagate in the human body. However, the generation of shear waves by acoustic vibrators is a relatively complex problem, and the directivity patterns of shear waves produced by the usual vibrators are more complicated than those obtained for longitudinal ultrasonic transducers. To extract shear modulus parameters from the shear wave propagation in soft tissues, it is important to understand and to optimize the directivity pattern of shear wave vibrators. This paper is devoted to a careful study of the theoretical and the experimental directivity pattern produced by a point source in soft tissues. Both theoretical and experimental measurements show that the directivity pattern of a point source vibrator presents two very strong lobes for an angle around 35 degrees . This paper also points out the impact of the near field in the problem of shear wave generation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/58.775668

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 167

Metadata

Authors
Catheline, S., Thomas, J.-L., Wu, F., & Fink, M. A.
Venue
IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control
Published
1999-07
Volume
46
Issue
4
Pages
1013-1019
ISSN
0885-3010 (ISSN-L)
OpenAlex
W2021123569
Cited by
167
References
1
FWCI
3.65
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Diffraction field of a low frequency vibrator in soft tissues using transient elastography. https://app.cochat.ai/papers/10.1109/58.775668
The paper
Catheline, S., Thomas, J.-L., Wu, F., & Fink, M. A. (1999). Diffraction field of a low frequency vibrator in soft tissues using transient elastography. IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control. https://doi.org/10.1109/58.775668

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.