Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 427

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

A review of wireless SAW sensors

Pohl, A.·2000·IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control

Abstract

Wireless measurement systems with passive surface acoustic wave (SAW) sensors offer new and exciting perspectives for remote monitoring and control of moving parts, even in harsh environments. This review paper gives a comprehensive survey of the present state of the measurement systems and should help a designer to find the parameters required to achieve a specified accuracy or uncertainty of measurement. Delay lines and resonators have been used, and two principles have been employed: SAW one-port devices that are directly affected by the measurand and SAW two-port devices that are electrically loaded by a conventional sensor and, therefore, indirectly affected by the measurand. For radio frequency (RF) interrogation, time domain sampling (TDS) and frequency domain sampling (FDS) have been investigated theoretically and experimentally; the methods of measurement are described. For an evaluation of the effects caused by the radio interrogation, we discuss the errors caused by noise, interference, bandwidth, manufacturing, and hardware tuning. The system parameters, distance range, and measurement uncertainty are given numerically for actual applications. Combinations of SAW sensors and special signal processing techniques to enhance accuracy, dynamic range, read out distance, and measurement repetition rate (measurement bandwidth) are presented. In conclusion, an overview of SAW sensor applications is given.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/58.827416

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 427

Metadata

Authors
Pohl, A.
Venue
IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control
Published
2000-03
Volume
47
Issue
2
Pages
317-332
ISSN
0885-3010 (ISSN-L)
OpenAlex
W2117883807
Cited by
427
References
2
FWCI
4.38
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A review of wireless SAW sensors. https://app.cochat.ai/papers/10.1109/58.827416
The paper
Pohl, A. (2000). A review of wireless SAW sensors. IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control. https://doi.org/10.1109/58.827416

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.