The DOI matches its Crossref record.
Development of a large static VAr generator using self-commutated inverters for improving power system stability
Abstract
A static VAr generator (SVG) using self-commutated inverters of 80 MVA capacity was developed and successfully applied to an annual 154 KV power system to stabilize the power system. The SVG consists of 48 pulse multiple inverters whereby gate turn-off (GTO) thyristors are applied. After installing it at a power system site, a field test was conducted to confirm the system stabilizing effect. The test results displayed the expected performance, and the SVG was proven to be effective power system stabilizer. The outline of the 80 MVA SVG, technical features, and the test results are described.>
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Control and Experiment of Pulsewidth-Modulated Modular Multilevel Converters
Hagiwara, M., & Akagi, H. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2014236 · Cited by 1,565
A multilevel voltage-source inverter with separate DC sources for static VAr generation
Peng, F. Z., Lai, J.-S., McKeever, J., & VanCoevering, J. (2002) · IAS '95. Conference Record of the 1995 IEEE Industry Applications Conference Thirtieth IAS Annual Meeting · doi:10.1109/ias.1995.530626 · Cited by 847
A comparison of high-power converter topologies for the implementation of FACTS controllers
Soto, D., & Green, T. C. (2002) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2002.803217 · Cited by 288
A power line conditioner using cascade multilevel inverters for distribution systems
Peng, F. Z., McKeever, J. W., & Adams, D. J. (2002) · IAS '97. Conference Record of the 1997 IEEE Industry Applications Conference Thirty-Second IAS Annual Meeting · doi:10.1109/ias.1997.629028 · Cited by 283
Metadata
- Authors
- Mori, S., Matsuno, K., Hasegawa, T., Ohnishi, S., Takeda, M., Seto, M., Murakami, S., & Ishiguro, F.
- Venue
- IEEE Transactions on Power Systems
- Published
- 1993
- Volume
- 8
- Issue
- 1
- Pages
- 371-377
- ISSN
- 0885-8950 (ISSN-L)
- OpenAlex
- W2162915068
- Cited by
- 319
- References
- 0
- FWCI
- 2.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Development of a large static VAr generator using self-commutated inverters for improving power system stability. https://app.cochat.ai/papers/10.1109/59.221218
- The paper
- Mori, S., Matsuno, K., Hasegawa, T., Ohnishi, S., Takeda, M., Seto, M., Murakami, S., & Ishiguro, F. (1993). Development of a large static VAr generator using self-commutated inverters for improving power system stability. IEEE Transactions on Power Systems. https://doi.org/10.1109/59.221218
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.