The DOI matches its Crossref record.
Decision trees for real-time transient stability prediction
Abstract
The ability to rapidly acquire synchronized phasor measurements from around the system opens up new possibilities for power system protection and control. This paper demonstrates how decision trees can be constructed offline and then utilized online for predicting transient stability in real-time. Primary features of the method include building a single tree for all fault locations, using a short window of realistic-precision post-fault phasor measurements for the prediction, and testing robustness to variations in the operating point. Several candidate decision trees are tested on 40,800 faults from 50 randomly generated operating points on the New England 39 bus test system.>
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 33
- brickell, 1979, Simulation of Staged Tests in the Ontario Hydro Northwestern Region, PICA Proc, 357
- wehenkel, 1993, Decision tree based transient stability assessment?a case study, IEEE PES Winter Meeting
- atlas, 1990, Advances in neural information processing systems, 2, 622
- van cutsem, 1991, Decision trees for detecting emergency voltage conditions, Procs of the 2nd Int NSF Workshop on Bulk Power System Voltage Phenomena?Voltage Stability and Security, 229
- 10.1109/59.32591 · doi:10.1109/59.32591
- 10.1109/59.131067 · DOI
- 10.1109/ISCAS.1988.15305 · doi:10.1109/iscas.1988.15305
- 10.1109/59.193853 · DOI
- 10.1016/0005-1098(91)90010-Y · DOI
- 10.1016/0031-3203(93)90060-A · DOI
- hunt, 1966, Experiments in Induction
- 10.1109/TC.1977.1674849 · DOI · Paper page
- 10.1109/TPAMI.1982.4767278 · DOI · Paper page
- 10.1080/01621459.1988.10478652 · DOI · Paper page
- 10.1109/TPAS.1969.292387 · doi:10.1109/tpas.1969.292387
- 10.1109/21.97458 · DOI · Paper page
- breiman, 1984, Classification and Regression Trees
- 10.1109/TPAS.1983.317895 · doi:10.1109/tpas.1983.317895
- 10.1109/TPWRS.1987.4335264 · doi:10.1109/tpwrs.1987.4335264
- 10.1109/TPAS.1974.294016 · doi:10.1109/tpas.1974.294016
- 10.1080/07313568808909340 · doi:10.1080/07313568808909340
- 10.1109/TPWRS.1986.4334984 · doi:10.1109/tpwrs.1986.4334984
- 10.1109/PICA.1989.38973 · doi:10.1109/pica.1989.38973
- 10.1109/59.32481 · DOI · Paper page
- phadke, 1991, Control and Dynamic Systems, 43, 335
- 10.1007/978-1-4613-1635-0 · DOI · Paper page
- van cutsem, 1993, decision tree approaches to voltage security assessment, Generation Transmission and Distribution [see also IEE Proceedings-Generation Transmission and Distribution] IEE Proceedings C, 140, 189, 10.1049/ip-c.1993.0029 · doi:10.1049/ip-c.1993.0029
- 10.1109/67.207465 · doi:10.1109/67.207465
- 10.1109/61.277716 · doi:10.1109/61.277716
- 10.1109/59.14597 · DOI
- 10.1109/TPAS.1983.318075 · doi:10.1109/tpas.1983.318075
- 10.1109/TPWRS.1986.4334955 · doi:10.1109/tpwrs.1986.4334955
- kretsinger, 1993, Parallel Decision Trees for the Real-Time Prediction of Synchronized Groups of Unstable Electric Generators
Cited by
Arrieta, A. B., Díaz-Rodríguez, N., Del Ser, J., Bennetot, A., Tabik, S., Barbado, A., García, S., Gil-López, S., Molina, D., Benjamins, R., et al. (2019) · arXiv · doi:10.48550/arxiv.1910.10045 · Cited by 11,321
Barredo Arrieta, A., Díaz-Rodríguez, N., Del Ser, J., Bennetot, A., Tabik, S., Barbado, A., Garcia, S., Gil-Lopez, S., Molina, D., Benjamins, R., et al. (2020) · Information Fusion · doi:10.1016/j.inffus.2019.12.012 · Cited by 10,423
“Many applications of these models fall out of the fields of computation and AI (even information technologies), meaning that experts from other fields usually feel comfortable interpreting the outputs of these models [183, 184, 185].”
Automatic Construction of Decision Trees from Data: A Multi-Disciplinary Survey
Murthy, S. K. (1998) · Data Mining and Knowledge Discovery · doi:10.1023/a:1009744630224 · Cited by 991
A survey of online failure prediction methods
Salfner, F., Lenk, M., & Malek, M. (2010) · ACM Computing Surveys · doi:10.1145/1670679.1670680 · Cited by 560
Gomez, F. R., Rajapakse, A. D., Annakkage, U. D., & Fernando, I. T. (2011) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2010.2082575 · Cited by 407
Support Vector Machines for Transient Stability Analysis of Large-Scale Power Systems
Moulin, L. S., daSilva, A. P. A., El-Sharkawi, M. A., & MarksII, R. J. (2004) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2004.826018 · Cited by 360
An Online Dynamic Security Assessment Scheme Using Phasor Measurements and Decision Trees
Sun, K., Likhate, S., Vittal, V., Kolluri, V. S., & Mandal, S. (2007) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2007.908476 · Cited by 337
Decision tree-based fault detection and classification in solar photovoltaic arrays
Zhao, Y., Yang, L., Lehman, B., de Palma, J.-F., Mosesian, J., & Lyons, R. (2012) · 2012 Twenty-Seventh Annual IEEE Applied Power Electronics Conference and Exposition (APEC) · doi:10.1109/apec.2012.6165803 · Cited by 268
Decision Tree-Based Online Voltage Security Assessment Using PMU Measurements
Diao, R., Sun, K., Vittal, V., O'Keefe, R. J., Richardson, M. R., Bhatt, N., Stradford, D., & Sarawgi, S. K. (2009) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2009.2016528 · Cited by 268
Synchrophasor Measurement Technology in Power Systems: Panorama and State-of-the-Art
Aminifar, F., Fotuhi-Firuzabad, M., Safdarian, A., Davoudi, A., & Shahidehpour, M. (2014) · IEEE Access · doi:10.1109/access.2015.2389659 · Cited by 261
Survey on Explainable AI: Techniques, challenges and open issues
Abusitta, A., Li, M. Q., & Fung, B. C. M. (2024) · Expert Systems with Applications · doi:10.1016/j.eswa.2024.124710 · Cited by 98
Metadata
- Authors
- Rovnyak, S., Kretsinger, S., Thorp, J., & Brown, D.
- Venue
- IEEE Transactions on Power Systems
- Published
- 1994
- Volume
- 9
- Issue
- 3
- Pages
- 1417-1426
- ISSN
- 0885-8950 (ISSN-L)
- OpenAlex
- W2095756634
- Cited by
- 232
- References
- 0
- FWCI
- 3.90
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.