The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
A three-phase power flow method for real-time distribution system analysis
Abstract
This paper presents a three-phase power flow solution method for real-time analysis of primary distribution systems. This method is a direct extension of the compensation-based power flow method for weakly meshed distribution systems from single phase to three-phase, with the emphasis on modeling of dispersed generation (PV nodes), unbalanced and distributed loads, and voltage regulators and shunt capacitors with automatic local tap controls. The method proposed here is capable of addressing these modeling challenges while still maintaining a high execution speed required for real-time application in distribution automation systems. The paper also includes test results from the application of a computer program developed based on the proposed method to large primary electric distribution systems.>
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A compensation-based power flow method for weakly meshed distribution and transmission networks
Shirmohammadi, D., Hong, H. W., Semlyen, A., & Luo, G. X. (1988) · IEEE Transactions on Power Systems · doi:10.1109/59.192932 · Cited by 1,182
Self-citationDistribution system power flow analysis-a rigid approach
Chen, T.-H., Chen, M.-S., Hwang, K.-J., Kotas, P., & Chebli, E. A. (1991) · IEEE Transactions on Power Delivery · doi:10.1109/61.85860 · Cited by 495
Efficient load flow for large weakly meshed networks
Luo, G. X., & Semlyen, A. (1990) · IEEE Transactions on Power Systems · doi:10.1109/59.99382 · Cited by 389
A multiphase harmonic load flow solution technique
Xu, W., Martí, J. R., & Dommel, H. W. (1991) · IEEE Transactions on Power Systems · doi:10.1109/59.131060 · Cited by 158
Rajicic, D., Ackovski, R., & Taleski, R. (1994) · IEEE Transactions on Power Delivery · doi:10.1109/61.296308 · Cited by 105
Cited by
Three-phase power flow calculations using the current injection method
Garcia, P. A. N., Pereira, J. L. R., Carneiro, S., da Costa, V. M., & Martins, N. (2000) · IEEE Transactions on Power Systems · doi:10.1109/59.867133 · Cited by 438
Power flow in four-wire distribution networks—General approach
Ciric, R. M., Feltrin, A. P., & Ochoa, L. F. (2003) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2003.818597 · Cited by 265
Khushalani, S., Solanki, J. M., & Schulz, N. N. (2007) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2007.901476 · Cited by 219
Koirala, A., Van Acker, T., D’hulst, R., & Van Hertem, D. (2022) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2021.111899 · Cited by 118
(2005) · Research Explorer (The University of Manchester) · Cited by 54
Metadata
- Authors
- Cheng, C. S., & Shirmohammadi, D.
- Venue
- IEEE Transactions on Power Systems
- Published
- 1995-05
- Volume
- 10
- Issue
- 2
- Pages
- 671-679
- ISSN
- 0885-8950 (ISSN-L)
- OpenAlex
- W2104179704
- Cited by
- 854
- References
- 5
- FWCI
- 6.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A three-phase power flow method for real-time distribution system analysis. https://app.cochat.ai/papers/10.1109/59.387902
- The paper
- Cheng, C. S., & Shirmohammadi, D. (1995). A three-phase power flow method for real-time distribution system analysis. IEEE Transactions on Power Systems. https://doi.org/10.1109/59.387902
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.